EMC Directive 2014/30/EC:

 

 EN 60730-1:2011 Automatic electrical controls for household and similar use - 

Part 1: General requirements

 

 EN 61000-6-1:2007 Electromagnetic compatibility (EMC) - Part 6-1: Generic 

standards - Immunity for residential, commercial and light-industrial 

environments

 

 EN 61000-6-3:2007 Electromagnetic compatibility (EMC) - Part 6-3: Generic 

standards - Emission standard for residential, commercial and light-industrial 

environments Amendments A1:2011 and AC:2012 to EN 61000-6-3

 

WEEE Directive 2012/19/EC

 

RoHs Directive 2011/65/EC

WIRING AND CONNECTIONS

Terminal block

N

MOTOR

Regulated output to motor, neutral

L

Regulated output to motor,  line

Pe 

Protective earth terminal

N

RELA

Y

Unregulated output 230 VAC that can be activated manually 

via Modbus Holding register 14 or automatically in case of an 

RTVS1  alarm  

L

N

INPUT

Power supply, neutral

L

 Power supply, phase (230 VAC / 50—60 Hz)

TK

Input - TK monitoring for thermal motor protection

TK

 RJ45 master socket - to connect a Sentera HVAC transmitter for demand based 

fan speed control in automatic mode

Pin 1

24 VDC

Supply voltage

Pin 2 
Pin 3

A

Modbus RTU communication, signal A

Pin 4
Pin 5

/B

Modbus RTU communication, signal /B

Pin 6
Pin 7

GND

Ground, supply voltage

Pin 8

RJ45 gateway - to connect a computer with 3SModbus software, a Sentera 

internet gateway or a BMS system 

Pin 1

Do not connect to your computer

Pin 2 
Pin 3

A

Modbus RTU communication, signal A

Pin 4
Pin 5

/B

Modbus RTU communication, signal /B

Pin 6
Pin 7

Do not connect to your computer

Pin 8

/B

A

GND

24 VDC

8 mm

8 mm

8 mm

8 mm

RJ45

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

3

4

5

6

3

4

ATTENTION

Make sure you use cables with an appropriate diameter.

TRANSFORMER FAN SPEED CONTROLLER WITH 
MODBUS RTU COMMUNICATION

RTVS1

Summary of Contents for RTVS1

Page 1: ...Mounting and operating instructions TRANSFORMER FAN SPEED CONTROLLER WITH MODBUS RTU COMMUNICATION RTVS1 ...

Page 2: ...SCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 WIRING AND CONNECTIONS 5 MOUNTING INSTRUCTIONS IN STEPS 6 OPERATING INSTRUCTIONS 9 VERIFICATION OF INSTALLATION 11 TRANSPORT AND STORAGE 12 WARRANTY AND RESTRICTIONS 12 MAINTENANCE 12 TRANSFORMER FAN SPEED CONTROLLER WITH MODBUS RTU COMMUNICATION RTVS1 ...

Page 3: ...t is as dry as possible avoid condensation All installations shall comply with local health and safety regulations and local electrical standards and approved codes This product can only be installed by an engineer or a technician who has expert knowledge of the product and safety precautions Avoid contacts with energised electrical parts Always disconnect the power supply before connecting servic...

Page 4: ...mounted Selection can be made via RTVS1 Modbus holding register 20 TECHNICAL DATA Supply voltage 230 VAC 50 60 Hz Modbus RTU communication TK monitoring for thermal motor protection Operating modes Automatic from low to high or from high to low Fan speed based on input from external Sentera sensor or potentiometer connected to the RJ45 master socket Manual Fan speed based on user input via Modbus ...

Page 5: ... be activated manually via Modbus Holding register 14 or automatically in case of an RTVS1 alarm L N INPUT Power supply neutral L Power supply phase 230 VAC 50 60 Hz TK Input TK monitoring for thermal motor protection TK RJ45 master socket to connect a Sentera HVAC transmitter for demand based fan speed control in automatic mode Pin 1 24 VDC Supply voltage Pin 2 Pin 3 A Modbus RTU communication si...

Page 6: ...he warmer the device will get For example in a technical room the correct installation height can be of great importance Do not install the controller above heating equipment or heat sources 3 3 If maximum ambient temperature cannot be adhered to please provide extra forced ventilation cooling Not respecting the abovelisted rules can reduce service life and relieves the manufacturer of any respons...

Page 7: ...the 3SModbus software or Sensistant For the default factory setting see the Modbus register map The desired fan speed can be adjusted via Modbus holding register 14 For the complete Modbus register data refer to the product Modbus Register Map which is a separate document attached to the article code on the website and contains the registers list NOTE Optional settings 1 In automatic mode a Senter...

Page 8: ...lled on your computer The Modbus to USB converter CNVT USB RS485 allows you to connect a Sentera device to the USB port of your computer and to monitor or adjust the different parameters see Application examples 1 and 2 Application example 1 Manual mode control via Modbus holding register 14 CNVT USB RS485 Master RTVS1 A B GND Application example 2 Automatic mode demand based ventilation RTVS1 Sla...

Page 9: ...orward mode 3 1 Manual mode The value is taken by Holding Register 12 where you can set the desired output step see the steps and corresponding voltages in Table 1 above 3 2 Automatic modes When Auto mode has been selected the controller changes the five speeds automatically according to the values measured by the sensor connected to the RJ45 master socket There are two automatic modes 3 2 1 Autom...

Page 10: ... diagram below for an example with steps from 2 to 5 An example of Auto Reverse mode the steps threshold configuration is as follows Step 1 0 Step 2 75 Step 3 50 Step 4 25 Step 5 1 can be as low as 0 1 is given in Fig 5 below When the Input value is above 1 device switches to Step 5 above 25 Step 4 above 50 Step 3 above 75 Step 2 up to 100 When the Input value decreases the hysteresis delta is sub...

Page 11: ... the sensor if sensor is lost the article stays on the last step selected If both communications are lost device stays on the last step selected In Auto modes if there is no communication to the control monitoring station the article continues to operate autonomously while the sensor is connected 18 Sensor output register value number Select which sensor output will be used as input to the device ...

Page 12: ...n manufacturing Any modifications or alterations to the product after the date of publication relieve the manufacturer of any responsibilities The manufacturer bears no responsibility for any misprints or mistakes in this data MAINTENANCE In normal conditions this product is maintenance free If soiled clean with a dry or damp cloth In case of heavy pollution clean with a non aggressive product In ...

Reviews: