STC-GE83A
STC-GEC83A
User Guide
9
Rev 1.01
III. The Camera Output Timing Charts
A. The Horizontal Timing
1 CLK = 27.1605 nseconds
1. Color Bayer order (This information is only applicable to the STC-GEC83A)
B. The Vertical Timing
1. Full Scanning
1 H = 34.493 µseconds, 36.42113 Hz
R1
Gr1
R2
Gb1
Gb2
B1
Gr2
B2
Video out
Line 1
・・・
Video out
Line 2
LVAL
R3
Gb3
Gr3
B3
・・・
・・・
・・・
・・・
・・・
246 CLK
1024 CLK
Video out
LVAL
Horizontal blanking
1270 CLK
One horizontal (1H)
1024 CLK
246 CLK
246 CLK
Video output
246 CLK
94
CLK
152 CLK
FVAL
28H
768H
Video out
FVAL
Vertical blanking
796H
One vertical (1V)
768H
28H
28H
Video output
1
2
767
768
28H
LVAL