STC-GE83A
STC-GEC83A
User Guide
16
Rev 1.01
2. Exposure Timing with the Positive Polarity Trigger Signal
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 30 CLK.
Please input a trigger signal with more than 31 CLK pulse width.
Note 2: The exposure will start 110 CLK after the rising edge of the trigger signal.
3. Exposure Timing with the Negative Polarity Trigger Signal
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 30 CLK.
Please input a trigger signal with more than 31 CLK pulse width.
Note 2: The exposure will start 110 CLK after the rising edge of the trigger signal.
Input Trigger signal
Exposure time
T1'
SUB
SG
Exposure time: T1' = Preset exposure time
Filtering *Note.1
30CLK
Trigger signal
(With Photocoupler delay)
Less than
5 useconds
Input Trigger signal
Exposure time
T1'
SUB
SG
Exposure time: T1' = Preset exposure time
Filtering *Note.1
30CLK
Trigger signal
(With Photocoupler delay)
Less than
60 useconds