Warning Display
The breath sample was not strong enough for measurement.
After warming automatically, please blow strong and steady during sampling.
The battery power is low. Please replace the batteries.
If you test over 1,000 tests, iSOBER 10 displays “CAL” sign.
Please contact calibration service provider.
Sensor error – Please contact a service provider.
iSOBER 10 has Bluetooth paired with iSOBER application.
It will be off in 5 minutes if there is no communication with mobile app.
Specification
Sensor type
Accuracy
Indication of B.A.C
Warm up time
Response time
Mouthpiece
Power supply
Weight
Dimensions (Inches)
Temperature conditions
Data connecting
Calibration interval
Fuel cell sensor
±10% at 0.050 %BAC
0.000 to 0.400%BAC by FND (segment type) Display
3 seconds~4 minutes
within 10 seconds at 0.100%BAC
Provided Individual packed mouthpiece
Two 1.5V “AAA” Alkaline batteries
2.94 oz (Including batteries)
4.1(H) X 2.1(W) X 0.7(T)
Operation 41°F to 104°F / Storage 32°F to 122°F
Bluetooth BLE
Every 12 months or 1,000 tests (Whichever comes first)