background image

Warning Display

The breath sample was not strong enough for measurement. 

After warming automatically, please blow strong and steady during sampling.

The battery power is low. Please replace the batteries.

If you test over 1,000 tests, iSOBER 10 displays “CAL” sign. 

Please contact calibration service provider. 

Sensor error – Please contact a service provider.

iSOBER 10 has Bluetooth paired with iSOBER application. 

It will be off in 5 minutes if there is no communication with mobile app.

Specification

Sensor type 

Accuracy 

Indication of B.A.C

Warm up time

Response time

Mouthpiece

Power supply

Weight 

Dimensions (Inches)

Temperature conditions

Data connecting

Calibration interval

Fuel cell sensor 

±10% at 0.050 %BAC

0.000 to 0.400%BAC by FND (segment type) Display

3 seconds~4 minutes

within 10 seconds at 0.100%BAC

Provided Individual packed mouthpiece

Two 1.5V “AAA” Alkaline batteries

2.94 oz (Including batteries)

4.1(H) X 2.1(W) X 0.7(T)

Operation 41°F to 104°F / Storage 32°F to 122°F

Bluetooth BLE

Every 12 months or 1,000 tests (Whichever comes first)

Summary of Contents for iSOBER 10

Page 1: ...ng The enhanced sensor quality check function Self Diagnosis System SDS on an app verifies the quality of breathalyzer s sensor and make sure the accuracy and reliable test result Contents Breathalyzer Zipper case Mouthpieces x5 AAABatteries x2 Outer box and User s manual Components BAC Clear WHITE FND type 3 Decimal point e g Displaying 010 means 0 010 BAC Measurement unit 2AAA Alkaline Batteries...

Page 2: ...laying e g Total 6 tests performed after calibration Dot in the first displaying means the thousands 2 Warming up takes a few seconds until displaying bLo it means blow sign 3 Blow through the mouthpiece for 4 seconds steadily without stops the unit gives beeping sound during the breath sampling and stop blowing when hearing click clack sound from the unit 4 The result displays for 10 seconds and ...

Page 3: ...y the unit is not paired with a mobile application Make sure the activation of Bluetooth on your mobile device and turn on iSOBER 10 unit again 4 The unit will be ready to blow status with showing bLo blow 5 Blowing through the mouthpiece into the unit for 4 seconds following guides ofApp 6 If the camera mode is on the camera of your mobile device will take a picture while blowing Camera mode coul...

Page 4: ...cause of improper use and incorrect result 2 Do not blow smoke saliva or other contaminants into the mouthpiece as the sensor may become damaged 3 Do NOT use iSOBER 10 as a tool to drink and drive 4 Keep out of extreme temperatures and out of the reach of children 5 Please do not use manganese battery Use alkaline battery only 6 To maintain the accuracy of the iSOBER 10 it must be re calibrated ev...

Page 5: ...off in 5 minutes if there is no communication with mobile app Specification Sensor type Accuracy Indication of B A C Warm up time Response time Mouthpiece Power supply Weight Dimensions Inches Temperature conditions Data connecting Calibration interval Fuel cell sensor 10 at 0 050 BAC 0 000 to 0 400 BAC by FND segment type Display 3 seconds 4 minutes within 10 seconds at 0 100 BAC Provided Individ...

Page 6: ...product to determine whether or the extent to which a test subject s mental or physical functioning or judgment may be impaired by blood alcohol including whether the test subject is intoxicated under any definition of that word Sentech USAINC expressly disclaims any liability for direct indirect incidental special or consequential damages of any nature under any legal theory Any act or failure to...

Page 7: ...BY LAW THIS WARRANTYAND THE REMEDIES SET FORTHABOVEARE EXCLUSIVEAND IN LIEU OFALL OTHER WARRANTIES REMEDIESAND CONDITIONS WHETHER ORAL OR WRITTEN STATUTORY EXPRESS OR IMPLIED AS PERMITTED BYAPPLICABLE LAW SENTECH USAINC SPECIFICALLY DISCLAIMSANYANDALL STATUTORY OR IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITYAND FITNESS FORAPARTICULAR PURPOSEAND WARRANTIESAGAINST HI...

Page 8: ...ries states and provinces do not allow the exclusion or limitation of incidental or consequential damages or allow limitations on how long an implied warranty or condition may last so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary by country state or province This Limited Warranty is governed by an...

Reviews: