Introduction
MPS-4100 product guide • • • b - 3
Installing the Com card
No special calibration equipment or tools are required to install the
Communications Interface Card:
•
set the network device address and baud rate on the DIP-switches
•
make the network wiring connections on the removable terminal blocks (data
grade shielded cable is recommended)
•
set up the Model MPS-4100 Receiver card for network operation
•
plug the card into P1 (XPNDR CONNECT) on the Model MPS-4100 Receiver
unit PCB
•
attach the ground strap to the ground screw
Setting the network device address
Each StarNeT 1000 network device requires a unique address. Refer to the site
plan for the network device address assigned to the MPS-4100 Microwave system.
The address must be between 0 and 127 and is set on DIP-switch S2 (see
Figure b-2).
WARNING: Disconnect the power source to the MPS-4100 microwave before
installing the card
.
CAUTION: Observe proper ESD handling procedures when working on the card
.
CAUTION: It requires considerable force to install the interface card on P1 of the
MPS-4100 receiver
. Apply firm, even pressure along the card edge
while installing the card. Avoid twisting the card or uneven pressure.
CAUTION: Connect the Interface card ground strap to the ground stud on the
MPS-4100 Receiver enclosure.
A good earth ground is essential for
transient protection.
Figure b-2 StarNeT 1000 network device address settings
SW2 - device address
(0 - 127)
not used
address
1
2
3
4
5
6
7
0
1
2
3
4
l
8
l
16
l
32
l
64
l
126
127
ON ON ON ON ON ON ON
OFF ON ON ON ON ON ON
ON OFF ON ON ON ON ON
OFF OFF ON ON ON ON ON
ON ON OFF ON ON ON ON
| | | | | | |
ON ON ON OFF ON ON ON
| | | | | | |
ON ON ON ON OFF ON ON
| | | | | | |
ON ON ON ON ON OFF ON
| | | | | | |
ON ON ON ON ON ON OFF
| | | | | | |
ON OFF OFF OFF OFF OFF OFF
OFF OFF OFF OFF OFF OFF OFF
switch position
set address
1
8
switch setting
for address 0
O
N