On Mode
Reset
Factory
Defaults
Switch
Mode
LED
Operation
Predictive
Exit
Time
Microphone
Grace Period
Occupancy
Time
Delay
Photocell
Set-Pt
Minimum
On Time
Manual On
Grace
Period
Dual
Technology
(Microphonics
TM
)
Predictive
Grace
Time
4x
5x
7x
9x
10x
2x
3x
12x
11x
13x
15x
16x
PRESS BUTTON
3.
While LED
flashes
back current
setting 10x...
OPERATIONAL SETTINGS
_________________________________________________________________________________________________
PROGRAMMING INSTRUCTIONS
______________________________________________________________________________________
PRESS BUTTON
30 sec
20 min
30 min
17.5 min
15.0 min
12.5 min
10 min
5.0 min
2.5 min
7.5 min
1x
13x
2x
3x
4x
5x
6x
7x
8x
9x
1.
While LED
flashes back new
setting 10x...
5.
On Mode
Reset
Factory
Defaults
Switch
Mode
LED
Operation
Predictive
Exit
Time
Microphone
Grace Period
Occupancy
Time
Delay
Photocell
Set-Pt
Minimum
On Time
Manual On
Grace
Period
Dual
Technology
(Microphonics
TM
)
Predictive
Grace
Time
4x
5x
7x
9x
10x
2x
3x
12x
11x
13x
15x
16x
PRESS BUTTON
4.
1.
5.
6.
LED FLASHES
CONFIRMATION
TWICE
PROGRAMMING
COMPLETE
7.
7.
Operational settings can be changed via the push-button sequence outlined below (note the example used is for changing occupancy time delay).
e.g., 5 flashes is default
10 min time delay
e.g., press 4x
to change
to 7.5 min
e.g., 4 flashes
indicates new
7.5 min time
delay setting
e.g., press 2x to
save and exit
2.
3.
e.g., press 2x for
Occupancy Time
Delay
NOTE: (
*
) Indicates factory default (unless otherwise marked)
C
US LISTED
Sheet#: IS-WSX-003
2
= Occupancy Time Delay
Time sensor keeps lights on after last occupancy detection.
1
30 sec
4
7.5 min
7
15.0 min
13
30.0 min
2
2.5 min
5
10.0 min*
8
17.5 min
3
5.0 min
6
12.5 min
9
20.0 min
For additional time settings, contact technical support at
1.800.PASSIVE
3
= On Mode
Automatic On turns lights on when occupancy is detected. Manual On
requires a button press to turn the lights on. Reduced Turn-On directs
the sensor to only detect large motions, such as a person entering
a room. Weaker signals, such as reflections from glass, are
ignored. Once lights are on, the sensor returns to maximum
sensitivity.
1
Automatic On*
2
Manual On**
3
Reduced Turn-On
* Standard Factory Default
** Factory Default for -SA and -NL versions
4
= Switch Modes
These modes dictate switch functionality. Pressing the button
in Override Off mode (setting 1) turns off and keeps lights off
until pressed again. Disabling the Switch (setting 2) prevents the
button from turning the lights on.
Predictive Mode (setting 3) automatically determines if a user
has left the room after the lights are switched off. It does this
by monitoring the space for a period after the button is pressed
(Predictive Grace Time), following a certain delay (Predictive
Exit Time). If occupancy is detected the device will disable
auto-on and hold the lights off until manually switched. If no
occupancy is detected the sensor instantly reverts to auto-on
mode. (continued next column)
If Predictive Mode with Expiration (setting 4) is enabled, once
the sensor has disabled auto-on it will continue to monitor the
space. When no occupancy is detected for a duration equal to the
occupancy time delay, the sensor will revert to auto-on mode.
1
Override Off **
2
Switch Disable
3
Predictive Mode
4
Predictive Mode with Expiration*
* Standard Factory Default
** Factory Default for -SA and -NL versions
5
= Photocell Set-Point
The ambient light level at which the sensor prevents the lights
from initially turning on. Once on, the lights will remain on until
the occupancy time delay expires and turns them off.
1
Disabled*
6
4 fc
2
Auto Setpoint
7
8 fc
3
0.5 fc
8
16 fc
4
1 fc
9
32 fc
5
2 fc
10
64 fc
Note: Sensor will be changed to Automatic On mode if photocell
is enabled. Photocell not present in -NL versions. LED flashes
while Auto-Setpoint mode is running.
7
= LED Operation
Indicates behavior of device’s LED.
1
Occupancy Indication*
3
Disabled
2
Relay Indication
4
Override On***
*Standard Factory Default *** Factory Default for -NL version
9
= Restore Factory Defaults
Returns all functions to original settings.
1
Maintain Current*
2
Restore Defaults
10
= Minimum On Time
Required initial time for lamps to be on after each switch on,
regardless of occupancy status. Once met, lights resume
following occupancy time delay.
1
0 min (disabled)*
3
30 min
5
60 min
2
15 min
4
45 min
11 = Manual On Grace Period
Time period after lights automatically turn off that they can be
reactivated by motion. (Manual On (Semi-Auto) mode only).
1
0 sec
2
Unused
3
15 sec*
12 = Dual Technology (Microphonics
TM
)
Relative responsiveness of Microphonics detection. Included in
-PDT versions only.
1
Normal*
3
Medium
5
Phase Off
2
Off
4
Low
(15-10-5 min)
13 = Microphone Grace Period
Time period after lights are automatically turned off that they
can be voice reactivated. Included in -PDT versions only.
1
0 sec
3
20 sec
5
40 sec
7
60 sec
2
10 sec*
4
30 sec
6
50 sec
15 = Predictive Mode Exit Time
Time period after manually switching lights off for occupant to
leave the space.
1
5 sec
3
7 sec
5
9 sec
7
15 sec
9
30 sec
2
6 sec
4
8 sec
6
10 sec*
8
20 sec
16 = Predictive Mode Grace Time
Time period after Predictive Mode Exit Time that sensor
rescans the room for remaining occupants.
1
0 sec
3
10 sec
5
30 sec*
7
50 sec
2
5 sec
4
20 sec
6
40 sec
8
60 sec
WARRANTY
5-year limited warranty. Complete warranty terms located at
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
TITLE 20/24
ASSEMBLED in U.S.A.
5 YEAR WARRANTY