background image

1

2

3

4

 

3

 

1/8

LZR -S600

®

1. Relay 1 - Field 1
2. Relay 2 - Field 2
3. Error
4. Power

GREEN LED

RED LED

BLUE LED

ORANGE LED

LED 

FLASHES

QUICKLY

LED 

FLASHES 

NORMALLY

LED 

FLASHES 

SLOWLY

LED 
OFF

DETECTION

POWER ON

ERROR

NO

DETECTION

Adjustable bracket

Cable conduit

LED-signal

Visible
laser beams

Laser sweep
reception

Laser sweep
emission

Tilt angle
adjustments

Main connector

Front screens

Caution! Exposure

 to laser radiation.

Factory values

See the indicated page

for further information

LASER SCANNER FOR

OBJECT AND BUILDING SECURITY *

LED-SIGNAL

USED SYMBOLS

DESCRIPTION

USER’S GUIDE

*Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer.

Summary of Contents for LZR -S600

Page 1: ...Cable conduit LED signal Visible laser beams Laser sweep reception Laser sweep emission Tilt angle adjustments Main connector Front screens Caution Exposure to laser radiation Factory values See the...

Page 2: ...e device contains IR and visible red laser diodes IR laser CLASS 1 wavelength 905nm max output pulse power 75W Red laser CLASS 3R wavelength 650nm max output CW power 3mW Fasten the sensor firmly to a...

Page 3: ...sition the sensor correctly The grey area indicates the detection range Position the housing on the bracket Turn the sensor until the two triangles are face to face Position the bracket and fasten the...

Page 4: ...sponding mounting side with background Make sure you stay at a distance to avoid disturbances By choosing a value with background the sensor is protected against misuse The sensor memorizes the refere...

Page 5: ...IONS TEACH IN Field height Field width FIELD 2 FIELD 1 3 sec RED RED RED RED Before teach in you have 3 seconds to step out of the detection field 30 sec TEACH IN Wait for the sensor to learn its envi...

Page 6: ...TMENTS Relay configuration 1 Indoor 2 Outdoor LOW 3 Outdoor MEDIUM 4 Outdoor HIGH 0 size filter deactivated 1 5 cm 2 10 cm 3 15 cm 4 20 cm 1 Active NO 2 Passive NC 3 Passive NC 4 Active NO Passive NC...

Page 7: ...aterial in proximity to the sensor Verify the field size Check the position of the sensor Launch a new teach in Check mounting side setting If there is no background set the mounting side to value 3 t...

Page 8: ...typ 20 ms max 80 ms 2 electronic relays galvanic isolated polarity free 35 V DC 24 V AC 80 mA resistive t 5 ms t 5 ms ON OFF typ 30 0 7 V 20 mA 10 A 1 blue LED power on status 1 orange LED error stat...

Reviews: