background image

...

1

2

3

4

5

6

7

8

9

0

...

...

1

2

3

4

5

6

7

8

9

0

...

?

...

1

2

3

4

5

6

7

8

9

0

9

0

0

0

0

RED

RED

GREEN

OFF

x

 value*

Select parameter

RED

RED

RED

OFF

How to check one or more values?

How to reset to factory values?

*The number of green flashes indicates the 
value of the chosen parameter.

If the orange LED flashes 3X, the 
corresponding field has been defined by the 
teach-in function.

If the detection field width is for example 
4.2m, the LED sequence will be: 4X green, 
1 orange, 2X green.

How to adjust one or more parameters?

RED

RED

OFF

Select parameter

Set value

RED

RED

RED

OFF

Power supply 

OFF/ON

How to delete an access code?

RED

RED

OFF

Select code

1-4 digits

How to save an access code?

Enter code

RED

OFF

RED

RED

1-4 digits

REMOTE CONTROL

How to enter a remote control session?

30 minutes after power reset, the 
sensor locks the access to the 
remote control session. Cut and 
restore power supply. The remote 
control session is accessible again 
during 30 minutes.

If the red LED flashes quickly after unlocking the sensor

enter an access code. In case you do not know the access code, 
cut and restore power supply. No code is required to unlock 
during the first minute after powering.

After unlocking the red 
LED flashes and the 
remote control is 
accessible.

HOW TO USE

Summary of Contents for LZR-RS300

Page 1: ...ORANGE LED LED FLASHES QUICKLY LED FLASHES NORMALLY LED FLASHES SLOWLY LED OFF DETECTION POWER ON ERROR NO DETECTION Adjustable bracket Cable conduit LED signal Visible laser beams Laser sweep recept...

Page 2: ...x output pulse power 75W Red laser CLASS 3R wavelength 650nm max output CW power 3mW Fasten the sensor firmly to avoid vibrations If the sensor is used in environments where the temperature can descen...

Page 3: ...r the cable if possible Drill 4 holes as indicated on the mounting template Use the adhesive mounting template to position the sensor correctly The grey area indicates the detection range Position the...

Page 4: ...the bracket to avoid malfunctioning To unlock use a screwdriver The beams will stay activated for 15 minutes or can be turned off the same way Mounting side 1 LEFT with background 2 RIGHT with backgro...

Page 5: ...d 0 5 m 5 0 m Field 1 Field 2 0 5 m 5 0 m for a field width of 3 5 m only for field 2 1 Indoor 2 Outdoor LOW 3 Outdoor MEDIUM 4 Outdoor HIGH 1 Active NO 2 Passive NC 3 Passive NC 4 Active NO Passive N...

Page 6: ...arameter Set value RED RED RED OFF Power supply OFF ON How to delete an access code RED RED OFF Select code 1 4 digits How to save an access code Enter code RED OFF RED RED 1 4 digits REMOTE CONTROL H...

Page 7: ...ial in proximity to the sensor Verify the field size Check the position of the sensor Launch a new teach in Check mounting side setting If there is no background set the mounting side to value 3 to 5...

Page 8: ...erminal 5 W 1 8 A max 80 ms 35 V 2 m typ 20 ms max 80 ms 2 electronic relays galvanic isolated polarity free 35 V DC 24 V AC 80 mA resistive t 5 ms t 5 ms ON OFF typ 30 0 7 V 20 mA 10 A 1 blue LED pow...

Reviews: