REMOTE CONTROL
1
2
3
3
4
RED
RED
RED
RED
TEACH-IN
3 sec.
Before teach-in, you have 3
seconds to step out of the
detection field.
30 sec.
TEACH-IN
Wait for the sensor to learn its
environment.
During the teach-in, the sensor
learns the new reference distances to all
objects within its detection zone.
deletes its memory and
Before you launch a teach-in, the selected field size must be bigger than the desired field size.
CORRECT POSITIONING
Adjust the tilt angle of the
sensor.
Adjust the lateral position.
Activate the visible laser beams if
you need a visual aid.
Lock the position of the
bracket to avoid
malfunctioning.
To unlock, use a screwdriver.
The beams will stay activated
for 15 minutes or can be
turned off the same way.
Mounting side
1 LEFT with background
2 RIGHT with background
3 LEFT without background
4 RIGHT without background
5 MIDDLE without background
MOUNTING SIDE
Select the corresponding mounting side with
background.
By choosing a value with background, the sensor is
protected against misuse. The sensor memorizes the
reference to the floor and will signal a fault in case the
orientation of the sensor is changed.
The sensor learns its environment and automatically determines its detection field(s).
Both RED LEDs flash and the 3 red laser beams automatically light up during 30 seconds.
Make sure you stay at a distance
to avoid disturbances.