MOUNTING 

TEMPLA

TE

GABARIT

 DE MONT

AGE

BOHRSCHABLONE

42.5004-V1

MOUNTING 

TEMPLA

TE

GABARIT

 DE MONT

AGE

BOHRSCHABLONE

42.5004-V1

1

MOUNTING 

TEMPLA

TE

GABARIT

 DE MONT

AGE

BOHRSCHABLONE

42.5004-V1

2

+

-

YELLOW

WHITE

GREEN

PINK

GREY

RED

BROWN

BLUE

RELAY 1

RELAY 1

RELAY 2

RELAY 2

Monitoring

Monitoring

Power

Power supply  -

Field 2

Field 1 - Not used

Make a 

hole for the cable

 

if possible.

Drill 4 holes

 as indicated on the 

mounting template.

Use the adhesive mounting 
template

 to position the sensor 

correctly. The grey area 
indicates the detection range.

Position the housing

 on the 

bracket.

Turn the sensor

 until the 

two triangles are face to face.

Position the 

bracket

 and 

fasten the 4 screws

 firmly in 

order to avoid vibrations.

Plug the connector

 and 

position the cable in the slit.

Close the protection sheath

 

and fasten it firmly.

MOUNTING

Pass the cable at least 8-10 cm 
though the 

cable opening

.

If drilling an opening is not 
possible, use the cable conduits 
on the back side of the bracket

.

WIRING

Summary of Contents for LZR-RS300

Page 1: ...ORANGE LED LED FLASHES QUICKLY LED FLASHES NORMALLY LED FLASHES SLOWLY LED OFF DETECTION POWER ON ERROR NO DETECTION Adjustable bracket Cable conduit LED signal Visible laser beams Laser sweep recept...

Page 2: ...x output pulse power 75W Red laser CLASS 3R wavelength 650nm max output CW power 3mW Fasten the sensor firmly to avoid vibrations If the sensor is used in environments where the temperature can descen...

Page 3: ...r the cable if possible Drill 4 holes as indicated on the mounting template Use the adhesive mounting template to position the sensor correctly The grey area indicates the detection range Position the...

Page 4: ...the bracket to avoid malfunctioning To unlock use a screwdriver The beams will stay activated for 15 minutes or can be turned off the same way Mounting side 1 LEFT with background 2 RIGHT with backgro...

Page 5: ...d 0 5 m 5 0 m Field 1 Field 2 0 5 m 5 0 m for a field width of 3 5 m only for field 2 1 Indoor 2 Outdoor LOW 3 Outdoor MEDIUM 4 Outdoor HIGH 1 Active NO 2 Passive NC 3 Passive NC 4 Active NO Passive N...

Page 6: ...arameter Set value RED RED RED OFF Power supply OFF ON How to delete an access code RED RED OFF Select code 1 4 digits How to save an access code Enter code RED OFF RED RED 1 4 digits REMOTE CONTROL H...

Page 7: ...ial in proximity to the sensor Verify the field size Check the position of the sensor Launch a new teach in Check mounting side setting If there is no background set the mounting side to value 3 to 5...

Page 8: ...erminal 5 W 1 8 A max 80 ms 35 V 2 m typ 20 ms max 80 ms 2 electronic relays galvanic isolated polarity free 35 V DC 24 V AC 80 mA resistive t 5 ms t 5 ms ON OFF typ 30 0 7 V 20 mA 10 A 1 blue LED pow...

Reviews: