![Sensor Technology RWT420 User Manual Download Page 28](http://html1.mh-extra.com/html/sensor-technology/rwt420/rwt420_user-manual_1244037028.webp)
© Sensor Technology Ltd 2015
RWT3722R (Rev5)
RWT410/420 Series Torque Transducers - Standard Range
●
– Standard feature
◊
– Optional feature
RWT410/420
Series
Option
Code
Remarks
Torque, Speed, Power Outputs
RWT410
RWT420
Torque only
410
420
Torque & Speed
(60 pulses/rev)
411
User to specify RPM/FSD
when ordering
Torque & Speed
(360 pulses/rev)
412
Not yet available
Torque & Power
(60 pulses/rev)
413
User to specify Power/FSD
when ordering
Torque & Speed
(60 pulses/rev)
or Power
421
Outputs are user selectable
Torque & Speed
(360 pulses/rev)
or Power
422
Not yet available
Standard features
Keyed Shaft Ends
●
●
K
1Nm will have flats
Voltage output ±5v FSD (Fixed)
●
B
Voltage outputs from ±1v to ±10v FSD
and unipolar (Variable)
●
Output is user selectable
RS232 output
●
Torque Averaging and Torque Peak
●
Self Diagnostics
●
●
Internal temperature measurement
●
●
Value available on RWT420
series only
Deep grooved shielded bearings with oil
lubrication
●
●
Ingress Protection (IP) 54
●
●
Optional features
Plain Shaft Ends
◊
◊
P
Shaft length will be longer
than keyed end shafts –
consult factory for length
Splined Shaft Ends
◊
◊
T
Consult factory for details
Voltage output ±1v FSD (Fixed)
◊
A
In place of Option B
Voltage output ±10v FSD (Fixed)
◊
C
In place of Option B
Customer Specified Voltage Output
(Fixed)
◊
U
In place of Option B. User
to specify range/scale when
ordering
Current output 0-20mA (Fixed)
◊
D
In place of Voltage output
options
Current output 4-20mA (Fixed)
◊
E
In place of Voltage output
options
Current output 12±8mA (Fixed)
◊
V
In place of Voltage output
options
Current output 0-20mA, 4-20mA
& 12±8mA (Variable)
◊
F
Current output is user
selectable and in place of
Voltage output. However
user can reselect a Voltage
output, if required. (Note 8)
USB 2.0 full speed 12 Mbps Digital output
◊
G
CANbus output
◊
H
In place of RS232 ouput
High Speed Bearings
(See Note 9 below)
◊
◊
J
Sealed Bearings
◊
◊
S
Ingress Protection (IP) 65
(See Note 10 below)
◊
◊
L
Consult factory for maximum
speed allowance.
Note 8: 2 x analog channels available. Default settings are Channel 1 (voltage/current) – torque.
Channel 2 (voltage/current) – speed or power, if ordered.
Note 9: At very high speeds, for better balance the factory recommend plain or splined shafts.
Note 10: Transducers fitted for IP65 will have running speeds considerably reduced, increased drag torque and accuracy can
be affected.
Data parameters measured at +20°C
Sensor Technology Ltd reserves the right to change specification and dimensions without notice.