Sensit SCAL-400 Instruction Manual Download Page 9

9

8 / 12 

Log Review Screen 

This

 

screen

 

lets

 

you

 

review

 

all

 

the

 

logs

 

available

 

in

 

the

 

SCal

400s

 

local

 

database.

 

It

 

will

 

display

 

the

 

most

 

recent

 

log

 

first,

 

but

 

other

 

logs

 

can

 

be

 

viewed

 

by

 

using

 

the

 

“PREV”

 

and

 

“NEXT”

 

buttons.

 

NOTE:

 

you

 

cannot

 

see

 

logs

 

from

 

other

 

stations

 

or

 

SCal

N/D

 

databases.

 

Table

 

3

 

references

 

the

 

displayed

 

example.

 

 

 

 

Password Screen 

The

 

Password

 

Screen

 

provides

 

a

 

supervisor

 

level

 

of

 

protection

 

to

 

access

 

the

 

Supervisor

 

and

 

Test

 

Menus

 

and

 

the

 

menu

 

to

 

update

 

the

 

calibration

 

gas

 

information.

 

The

 

password

 

is

 

four

 

numbers

 

long.

 

Tapping

 

the

 

“CLEAR”

 

button

 

will

 

reset

 

the

 

boxes,

 

allowing

 

you

 

to

 

try

 

again.

 

After

 

you

 

enter

 

four

 

numbers,

 

the

 

password

 

will

 

automatically

 

be

 

checked.

 

Upon

 

providing

 

the

 

correct

 

password,

 

the

 

next

 

screen

 

will

 

be

 

displayed.

 

Entering

 

an

 

incorrect

 

password

 

will

 

change

 

the

 

screen

 

title

 

to

 

be

 

displayed

 

as

 

“WRONG

 

PASSWORD”

 

in

 

red.

 

After

 

three

 

unsuccessful

 

attempts,

 

the

 

password

 

screen

 

will

 

close

 

and

 

you

 

will

 

return

 

to

 

the

 

previous

 

screen.

 

 

Sample

 

image

 

of

 

the

 

Log

 

Review

 

Screen:

 

Table

 

3:

 

Log

 

Review

 

Screen

 

background

 

colors

 

and

 

descriptions

Type

 

Background

 

Color

 

Description

Serial

 

#

 

NA

 

Displays

 

the

 

serial number of

 

the

 

P400

 

unit

Type

 

NA

 

Displays

 

the type of

 

log:

 

BUMP/CAL

Result

 

Bar

 

Result

 

bar

 

is

 

divided

 

in

 

5

 

cells.

 

Each

 

cell

 

represents

 

sensor

 

calibration/bump

 

result.

 

RED

 

FAILED:

 

BUMP

 

FAILED

CAL

 

FAILED:

 

CALIBRATION

 

FAILED

 

ZERO

 

FAILED

 

YELLOW

 

CAL

 

GAS

 

FAILED:

 

Calibration

 

gas

 

supply

 

check

 

failed

GRAY

 

Sensor

 

Test

 

(calibration/bump)

 

is

 

skipped

 

by

 

user

GREEN

 

PASSED

 

Sample

 

image

 

of

 

the

 

Password

 

Screen:

Summary of Contents for SCAL-400

Page 1: ...N D E R S T A N D I N S T R U C T I O N S B E F O R E U S E FOR USE IN AREAS KNOWN TO BE FREE OF COMBUSTIBLE GAS HAZARDS FOR USE IN AREAS THAT ARE CLEAN AND DRY 851 Transport Drive Valparaiso IN 4638...

Page 2: ......

Page 3: ...en 7 Main Menu Screen 8 Calibration Gas Information Screen 8 Log Review Screen 9 Password Screen 9 Supervisor Menu Screen 10 12 Operation Set up 13 Operation System Activation 13 Operation P400 Testin...

Page 4: ...emperature 40 122 F 5 50 C Maximum inlet pressure 20psi Features Touch screen display LED status indicators Charging pins Communication pin Power connection RJ45 Serial Connections Cooling fan intake...

Page 5: ...t is referred to as a slot For each slot there are charger and communication connections as well as LEDs to indicate the status All testing functions require no user interaction The display is a touch...

Page 6: ...Screen only if no unit test is pending or in progress Sample image of the Main Screen Table 1 Main Screen background colors and descriptions Slot Screen Background color Status Description GRAY Empty...

Page 7: ...ttery WHITE CHARGING RED ALKALINE LOW BATTERY GREEN CHARGED ALKALINE OK 3 Data Transfer GRAY PENDING WHITE UPDATING RTC DOWNLOADING CALIBRATION LOG DOWNLOADING BUMP TEST LOG GREEN COMPLETED DATA TRANS...

Page 8: ...eight cells Each cell represents a single gas inlet valve The background colors and gas inlets are color coded and matched for easy identification The colors on the manifold label correspond to the co...

Page 9: ...omatically be checked Upon providing the correct password the next screen will be displayed Entering an incorrect password will change the screen title to be displayed as WRONG PASSWORD in red After t...

Page 10: ...SCal 400 application All available time zones will be listed Select the appropriate time zone and click UPDATE A message box will be displayed to indicate system will restart Click OK to continue 2 S...

Page 11: ...be present A copy of the database will be saved to the memory card every day The automatically saved backup files are named AUTO_DDMMYYYY sdf b BACKUP DATABASE This option will create a manual backup...

Page 12: ...libration bump test 12 PURGE TIME AFTER Amount of time in seconds the unit will purge the line with air after it completes a calibration bump test 13 SPECIALITY GAS PURGE Amount of time in seconds the...

Page 13: ...ot 4 If the instrument is off it will turn on automatically 5 The instrument will be bump tested and or calibrated as determined by the instrument setup 6 The instrument will recharge if needed Alkali...

Page 14: ...NOTES...

Page 15: ...NOTES...

Page 16: ...before warranty is rendered Units out of warranty will be repaired for a service charge Internal repair or maintenance must be performed by a Sensit Technologies authorized technician Violation will...

Reviews: