Detail Status Screen 

The

 

Detail

 

Status

 

Screen

 

provides

 

additional

 

details

 

about

 

the

 

P400

 

in

 

the

 

selected

 

slot.

 

This

 

provides

 

real

 

time

 

progress

 

of

 

data

 

transfer,

 

calibration

 

and

 

bump

 

test.

 

From

 

here

 

you

 

can

 

manually

 

perform

 

a

 

calibration

 

or

 

bump

 

test

 

by

 

tapping

 

the

 

appropriate

 

icon.

 

Table

 

2

 

references

 

the

 

displayed

 

example.

 

 

 

Sample

 

image

 

of

 

the

 

Detail

 

Status

 

Screen:

Table

 

2:

 

Detail

 

Status

 

Screen

 

description

 

Label

 

Type

 

Background

 

Color

 

Status

 

Description

1. Header

 

WHITE

 

WAKING

 

UP/DATA

 

TRANSFERRED/TEST

 

PENDING/WAITING

 

IN

 

QUEUE/IN

 

PROGRESS

 

RED

 

FAILED

 

BUMP

 

TEST

 

OR

 

CALIBRATION

GREEN

ALL

 

TEST

 

SUCCESSFULLY

 

COMPLETED

2. Battery

 

WHITE

 

CHARGING

RED

 

ALKALINE:

 

LOW

 

BATTERY

GREEN

CHARGED/ALKALINE:

 

OK

3.

 

Data

 

Transfer

   

GRAY

 

PENDING

WHITE

 

UPDATING

 

RTC/DOWNLOADING

 

CALIBRATION

 

LOG/DOWNLOADING

 

BUMP

 

TEST

 

LOG

 

GREEN

COMPLETED

 

DATA

 

TRANSFER

4. Unit

 

Autozero

   

GRAY

 

NOT

 

REQUIRED

WHITE

 

PENDING/PURGING/IN

 

PROGRESS

RED

 

FAILED

GREEN

PASSED

5. Sensor

   

Autozero

 

GRAY

 

PENDING

RED

 

FAILED

GREEN

PASSED

6. Unit

 

Calibration

 

GRAY

 

NOT

 

REQUIRED

WHITE

 

PENDING/PURGING/IN

 

PROGRESS

 

– DISPLAYS

 

ADC

 

COUNTS

 

OF

 

SENSOR

 

BEING

 

CALIBRATED

   

RED

 

FAILED

GREEN

PASSED

7. Sensor

 

Calibration

   

GRAY

 

PENDING

WHITE

 

IN

 

PROGRESS

YELLOW

 

CALIBRATION

 

GAS

 

SUPPLY

 

TEST

 

FAILED

RED

 

FAILED

GREEN

PASSED

8. Unit

 

Bump

 

Test

 

GRAY

 

NOT

 

REQUIRED

WHITE

 

PENDING/PURGING/IN

 

PROGRESS

RED

 

FAILED

GREEN

PASSED

9. Sensor

 

Bump

 

Test

   

GRAY

 

PENDING

WHITE

 

IN

 

PROGRESS

YELLOW

 

CALIBRATION

 

GAS

 

SUPPLY

 

TEST

 

FAILED

RED

 

FAILED

GREEN

PASSED

Summary of Contents for SCAL-400

Page 1: ...N D E R S T A N D I N S T R U C T I O N S B E F O R E U S E FOR USE IN AREAS KNOWN TO BE FREE OF COMBUSTIBLE GAS HAZARDS FOR USE IN AREAS THAT ARE CLEAN AND DRY 851 Transport Drive Valparaiso IN 4638...

Page 2: ......

Page 3: ...en 7 Main Menu Screen 8 Calibration Gas Information Screen 8 Log Review Screen 9 Password Screen 9 Supervisor Menu Screen 10 12 Operation Set up 13 Operation System Activation 13 Operation P400 Testin...

Page 4: ...emperature 40 122 F 5 50 C Maximum inlet pressure 20psi Features Touch screen display LED status indicators Charging pins Communication pin Power connection RJ45 Serial Connections Cooling fan intake...

Page 5: ...t is referred to as a slot For each slot there are charger and communication connections as well as LEDs to indicate the status All testing functions require no user interaction The display is a touch...

Page 6: ...Screen only if no unit test is pending or in progress Sample image of the Main Screen Table 1 Main Screen background colors and descriptions Slot Screen Background color Status Description GRAY Empty...

Page 7: ...ttery WHITE CHARGING RED ALKALINE LOW BATTERY GREEN CHARGED ALKALINE OK 3 Data Transfer GRAY PENDING WHITE UPDATING RTC DOWNLOADING CALIBRATION LOG DOWNLOADING BUMP TEST LOG GREEN COMPLETED DATA TRANS...

Page 8: ...eight cells Each cell represents a single gas inlet valve The background colors and gas inlets are color coded and matched for easy identification The colors on the manifold label correspond to the co...

Page 9: ...omatically be checked Upon providing the correct password the next screen will be displayed Entering an incorrect password will change the screen title to be displayed as WRONG PASSWORD in red After t...

Page 10: ...SCal 400 application All available time zones will be listed Select the appropriate time zone and click UPDATE A message box will be displayed to indicate system will restart Click OK to continue 2 S...

Page 11: ...be present A copy of the database will be saved to the memory card every day The automatically saved backup files are named AUTO_DDMMYYYY sdf b BACKUP DATABASE This option will create a manual backup...

Page 12: ...libration bump test 12 PURGE TIME AFTER Amount of time in seconds the unit will purge the line with air after it completes a calibration bump test 13 SPECIALITY GAS PURGE Amount of time in seconds the...

Page 13: ...ot 4 If the instrument is off it will turn on automatically 5 The instrument will be bump tested and or calibrated as determined by the instrument setup 6 The instrument will recharge if needed Alkali...

Page 14: ...NOTES...

Page 15: ...NOTES...

Page 16: ...before warranty is rendered Units out of warranty will be repaired for a service charge Internal repair or maintenance must be performed by a Sensit Technologies authorized technician Violation will...

Reviews: