GENERAL DESCRIPTION

SPECIFICATIONS

5

BACKLIT DISPLAY

SPEAKER
(ON BACK)

WARNING LED

16” FLEXIBLE
GOOSENECK

SOLID STATE
SENSOR

PUSH BUTTONS

BATTERY
COMPARTMENT

BATTERY SLEEVE
RETAINING SCREW

SENSOR
FILTER

PRODUCT FEATURES

SENSOR SPECIFICATIONS

TYPE

RESOLUTION

RANGE

ACCURACY

PPM

10ppm

0-990ppm

±10%

LEL

0.1%

0-100%LEL

±10%

PRODUCT SPECIFICATIONS

Size:

10” x 3” x 1.6” (254 x 76 x 41 mm)

Weight:

1.2 lbs. (544g)

Operational Temp:

 -20 to 40°C (-4 to 104° F)

Battery Life:

Alkaline: 50 hours continuous

The Sensit® HXG-2d is designed to detect combustible gases.
This instrument incorporates an advanced low power semicon-
ductor sensor to measure a wide variety of combustible gases
in both the PPM and %LEL range. The PPM readings auto-range
to %LEL when the concentration exceeds 990PPM (2%LEL meth-
ane). Optionally all readings can be set to a resolution of
0.1%LEL only (PPM off). An “on demand” backlight allows use in
dark environments. A user activated “TICK” control assists in
locating small gas leaks. Audible and visual alarms warn the
operator of hazards. The alarms can be set in either the PPM or
LEL modes. The default alarm is 10%LEL methane.

The instrument is adjusted at the factory for either methane or
propane as the primary gas, and is calibrated accordingly. The
primary gas can be selected when ordering.

The Sensit® HXG-2d meets US UL913 requirements when used
with approved batteries.

The  Sensit® HXG-2d is operated using approved alkaline bat-
teries only.

       WARNING: Never mix batteries of different age or type.

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for 906-00000-08

Page 1: ...inop erative from such defects the unit will be repaired or replaced at our option This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from alte...

Page 2: ...ion which if not avoided may result in minor or moderate injury NOTICE WARNING This safety symbol is used to indicate a potentially hazardous situa tion which if not avoided may result in serious inju...

Page 3: ...of combustible gases in both the PPM and LEL range The PPM readings auto range to LEL when the concentration exceeds 990PPM 2 LEL meth ane Optionally all readings can be set to a resolution of 0 1 LEL...

Page 4: ...battery compartment All Sensit HXG 2d instruments require 3 Duracell PC1400 batteries provide approximately 50 hours of continuous use A push button located in the center of the instrument activates a...

Page 5: ...ly inoperable or improperly zeroed at start up the display will show bAd BATTERYINSTALLATION REPLACEMENT 9 Continued on page 10 OPERATIONAND USE WARNING Always change batteries in an environment free...

Page 6: ...ark areas press and release the LIGHT ZERO button C to turn on the back light Press again to turn off 12 To turn instrument off push and hold the POWER MUTE button A for 5 6 seconds until OFF appears...

Page 7: ...r that does not meet the specifications listed in this manual may re quire calibration or replacement AnytimeitissuspectedtheSensit HXG 2disnotworkingproperly has read OL or has been exposed to silico...

Page 8: ...etpoint can be set in units of PPM 5 Press the B button once more until the display shows XXXppm This is the alarm setpoint it must be set to a PPM value greater than or equal to 100ppm to activate th...

Reviews: