background image

 

©2017 Sensing-labs 

Sensing Labs SenlabM PUL-LAB-

xx

NS 

 User guide 

Legals 

 
 

SENSING  LABS  SAS  reserves  the  right  to  make  corrections,  modifications, 
enhancements,  improvements  and  other  changes  to  its  products  and  services  at 
any time and to discontinue any product or service without notice. 
 
SENSING LABS products is not authorized for use in safety-critical applications 
(such as life support) where a failure of the product would reasonably be expected 
to cause severe personal injury or death, unless officers of the parties have executed 
an agreement specifically governing such use. 
 
Buyers confirm that they have all necessary expertise in the safety and regulatory 
ramifications  of  their  applications,  acknowledge  and  agree  that  they  are  solely 
responsible for all legal, regulatory and safety-related requirements concerning their 
products  and  any  use  of  the  product  in  such  safety-critical  applications, 
notwithstanding  any  applications-related  information  or  support  that  may  be 
provided by SENSING LABS SAS. 
 

 

©  2017  SENSING  LABS  SAS.  All  rights  reserved.  Sensing  Labs  logo,  are  registered 
trademarks of SENSING LABS SAS. All other brands and product names mentioned in 
this document are the property of their respective holders.  
This is a non-contractual document and specifications are subject to change at any 
time without notice. 
 
 
For more information about this software: 
website - http://www.sensing-labs.com 
support 

 

http://support.sensing-labs.com

 

 
Headquarters:  
SENSING LABS SAS. 
CAP OMEGA, 
rond point Benjamin Franklin 
34960 Montpellier cedex 02 

 France 

 

 

 

Summary of Contents for SenlabM PUL-LAB-13NS

Page 1: ...LABS SAS Cap Om ga Rond point Benjamin Franklin CS 39521 34960 Montpellier Cedex 2 France www sensing labs com support sensing labs com SenlabM PUL LAB xxNS User guide SENSING LABS VERSION 02 REV A JU...

Page 2: ...input is closed during a pulse the load resistor is low When the input is open the load resistor is high Any question about your meter compatibility Please contact your distributor Part number Casing...

Page 3: ...em are listed in the following table devEUI appEUI appKey appSkey NwkSkey netId devAddress Case 1 OTAA PUBLIC Typical configuration for Network Operator based architecture X required required Case 2 A...

Page 4: ...all or cabinet with a double sided adhesive tape Indoor versions Screw the rear side of the product to the wall with countersunk screws make sure the screw heads don t exceed from the plastic side onc...

Page 5: ...t as soon as the LED flashes If activation fails No solid LED ON 2sec Senlab will come back in storage mode After successful activation device will automatically send its START message Put Magnet 1 se...

Page 6: ...estarted on the field BOOL Configuration requests Parameter ID Description Type Unit Range Datalog configuration ID request_write_datalog_cfg log_period Device will measure every X minutes UINT16 Minu...

Page 7: ...the maximum battery level used for battery life calculation expressed in mAs Uplink message DATALOG FPort 3 format valid for one log per transmission only ID 1B BATTERY_LEVEL 1B Internal data n bytes...

Page 8: ...st request_reset_battery_level to the device using your application or the SLsetting support Indoor V2 have the capability to keep activation status during a few minutes so the process is 1 Open the c...

Page 9: ...ations of their applications acknowledge and agree that they are solely responsible for all legal regulatory and safety related requirements concerning their products and any use of the product in suc...

Reviews: