background image

 

©2017 Sensing-labs 

Sensing Labs SenlabM PUL-LAB-

xx

NS 

 User guide 

Provisioning of the device 

 
You have to be sure that your 

Senlab device has been well commissioned

 to be able to 

reach your LoRaWAN network. 

 

Contact if needed your distributor to get your Senlab configuration 

 

Required informations for provisionning the device into your LoRa system are listed 
in the following table : 

 

 

 

 

devEUI

 

appEUI

 

appKey

 

appSkey

 

NwkSkey

 

netId

 

devAddres

Case 1 : OTAA / PUBLIC 

Typical configuration for Network 
Operator based architecture

 

required  required

   

 

 

 

Case 2 : ABP / PUBLIC  

Typical configuration for Private 
mono gateway network

 

 

 

required

 

required

   

required

 

Case 3 : ABP / PRIVATE  

Sensing-Labs SLbase gateway 
configuration (local network)

 

optional

   

optional

 

optional

 

optional  optional

 

 

 

 

 

Warning, don’t unprovision device from your system before stopping it!

(refer application features to stop the application via RF)

Summary of Contents for SenlabM PUL-LAB-13NS

Page 1: ...LABS SAS Cap Om ga Rond point Benjamin Franklin CS 39521 34960 Montpellier Cedex 2 France www sensing labs com support sensing labs com SenlabM PUL LAB xxNS User guide SENSING LABS VERSION 02 REV A JU...

Page 2: ...input is closed during a pulse the load resistor is low When the input is open the load resistor is high Any question about your meter compatibility Please contact your distributor Part number Casing...

Page 3: ...em are listed in the following table devEUI appEUI appKey appSkey NwkSkey netId devAddress Case 1 OTAA PUBLIC Typical configuration for Network Operator based architecture X required required Case 2 A...

Page 4: ...all or cabinet with a double sided adhesive tape Indoor versions Screw the rear side of the product to the wall with countersunk screws make sure the screw heads don t exceed from the plastic side onc...

Page 5: ...t as soon as the LED flashes If activation fails No solid LED ON 2sec Senlab will come back in storage mode After successful activation device will automatically send its START message Put Magnet 1 se...

Page 6: ...estarted on the field BOOL Configuration requests Parameter ID Description Type Unit Range Datalog configuration ID request_write_datalog_cfg log_period Device will measure every X minutes UINT16 Minu...

Page 7: ...the maximum battery level used for battery life calculation expressed in mAs Uplink message DATALOG FPort 3 format valid for one log per transmission only ID 1B BATTERY_LEVEL 1B Internal data n bytes...

Page 8: ...st request_reset_battery_level to the device using your application or the SLsetting support Indoor V2 have the capability to keep activation status during a few minutes so the process is 1 Open the c...

Page 9: ...ations of their applications acknowledge and agree that they are solely responsible for all legal regulatory and safety related requirements concerning their products and any use of the product in suc...