©2017 Sensing-labs 

Sensing Labs SenlabM PUL-LAB-

xx

NS 

 User guide 

Security 

Electrical safety 

 

All circuits are SELV (Safety extra low voltage), including interface circuits which are only 
used for measurement (signals without power, these circuits are considered LPS). 

 

Battery replacement (Indoor version only) 

Replacement  battery  must  by  a  Lithium  3,6V  AA  type  with  50mA  min  of  supported 
continuous current 

 Contact your distributor to get original battery reference. 

 

Indoor V1

 will lost the activation status during the battery replacement, so the process is: 

1.

 

Open the casing 

2.

 

Remove the old battery * 

3.

 

Put the new battery 

4.

 

Close the casing 

5.

 

Activate the device (see “

Activation of the device

” chapter)

 

6.

 

Send the configuration request “

request_reset_battery_level

 to the device, using 

your application or the SLsetting support ** 

 

Indoor  V2

  have  the  capability  to  keep  activation  status  during  a  few  minutes,  so  the 

process is: 

1.

 

Open the casing 

2.

 

Remove the old battery and, 

during the same minute

, put the new battery 

3.

 

Check if the device activation is still OK (see 

Activation of the device

 chapter) 

4.

 

In case activation lost, you need to activate the device again * 

5.

 

Close the casing 

7.

 

Send the configuration request “

request_reset_battery_level

 to the device, using 

your application or the SLsetting support ** 

(*) current raw_index will be reset to zero 
(**) coming soon 

 
ATTENTION: 
EN: There is a risk of explosion if the battery is replaced by an incorrect type. Dispose of 
used batteries according to instructions. 

FR: Il y a risque d’explosion si la batterie est remplacée par une batterie de type incorre

ct. 

Mettre au rebut les batteries usagées conformément aux instructions.

  

 

Summary of Contents for SenlabM PUL-LAB-13NS

Page 1: ...LABS SAS Cap Om ga Rond point Benjamin Franklin CS 39521 34960 Montpellier Cedex 2 France www sensing labs com support sensing labs com SenlabM PUL LAB xxNS User guide SENSING LABS VERSION 02 REV A JU...

Page 2: ...input is closed during a pulse the load resistor is low When the input is open the load resistor is high Any question about your meter compatibility Please contact your distributor Part number Casing...

Page 3: ...em are listed in the following table devEUI appEUI appKey appSkey NwkSkey netId devAddress Case 1 OTAA PUBLIC Typical configuration for Network Operator based architecture X required required Case 2 A...

Page 4: ...all or cabinet with a double sided adhesive tape Indoor versions Screw the rear side of the product to the wall with countersunk screws make sure the screw heads don t exceed from the plastic side onc...

Page 5: ...t as soon as the LED flashes If activation fails No solid LED ON 2sec Senlab will come back in storage mode After successful activation device will automatically send its START message Put Magnet 1 se...

Page 6: ...estarted on the field BOOL Configuration requests Parameter ID Description Type Unit Range Datalog configuration ID request_write_datalog_cfg log_period Device will measure every X minutes UINT16 Minu...

Page 7: ...the maximum battery level used for battery life calculation expressed in mAs Uplink message DATALOG FPort 3 format valid for one log per transmission only ID 1B BATTERY_LEVEL 1B Internal data n bytes...

Page 8: ...st request_reset_battery_level to the device using your application or the SLsetting support Indoor V2 have the capability to keep activation status during a few minutes so the process is 1 Open the c...

Page 9: ...ations of their applications acknowledge and agree that they are solely responsible for all legal regulatory and safety related requirements concerning their products and any use of the product in suc...

Reviews: