Security
Electrical safety
All circuits are SELV (Safety extra low voltage), including interface circuits which are only
used for measurement (signals without power, these circuits are considered LPS).
Battery replacement (Indoor version only)
Replacement battery must by a Lithium 3,6V AA type with 50mA min of supported
continuous current
Contact your distributor to get original battery reference.
Indoor V1
will lost the activation status during the battery replacement, so the process is:
1.
Open the casing
2.
Remove the old battery *
3.
Put the new battery
4.
Close the casing
5.
Activate the device (see “
Activation of the device
” chapter)
6.
Send the configuration request “
request_reset_battery_level
”
to the device, using
your application or the SLsetting support **
Indoor V2
have the capability to keep activation status during a few minutes, so the
process is:
1.
Open the casing
2.
Remove the old battery and,
during the same minute
, put the new battery
3.
Check if the device activation is still OK (see
“
Activation of the device
”
chapter)
4.
In case activation lost, you need to activate the device again *
5.
Close the casing
7.
Send the configuration request “
request_reset_battery_level
”
to the device, using
your application or the SLsetting support **
(*) current raw_index will be reset to zero
(**) coming soon
ATTENTION:
EN: There is a risk of explosion if the battery is replaced by an incorrect type. Dispose of
used batteries according to instructions.
FR: Il y a risque d’explosion si la batterie est remplacée par une batterie de type incorre
ct.
Mettre au rebut les batteries usagées conformément aux instructions.