Maintenance and Troubleshooting
4.0 Maintenance and Troubleshooting
The following information is provided to help you keep your MS Series inverter/charger in optimum
operational condition.
4.1 Recommended Inverter and Battery Care
The MS Series inverter/charger is designed to provide you with years of trouble-free service. Even
though there are no user-serviceable parts, it is recommended that every 6 months you perform the
following maintenance steps to ensure optimum performance and extend the life of your batteries.
WARNING:
Prior to performing any checks, switch OFF both the AC and DC circuits.
• Visually inspect the batteries for cracks, leaks, or swelling—replace if necessary
• Use baking soda to clean and remove any electrolyte spills or buildups
• Check and tighten all battery hold-down clamps (if applicable)
• Clean/tighten all battery terminals and connecting cables [10 to 12 ft lbf (13.6 to 16.3 N-m)]
• Check and fi ll battery water levels (liquid lead acid batteries only)
• Check individual battery voltages (load test those that have a voltage diff erence of more
than 0.3 VDC from each other)—replace if necessary
• Check all cable runs for signs of chafi ng—replace if necessary
• Check the inverter’s cooling vents—clean as necessary
• Check/tighten the inverter’s internal AC terminal block connections [16 in-lbf (1.8 N-m)]
4.2 Storage for Mobile Installations
When placing the RV, boat or truck into storage, it is recommended that you perform the following
to ensure the system is properly shut down (or properly confi gured for storage). This is especially
important for maintaining the batteries.
• Perform the recommended maintenance steps listed in Section 4.1
• Fully charge the batteries
• Connect AC power (if available) and verify that the breaker to the inverter’s input is
switched ON (to allow battery charging)
• Verify the inverter is switched OFF
• Switch OFF all unnecessary AC and DC loads
• Disable the AGS (if installed) when the RV, boat, or truck is in a confi ned storage area
WARNING:
If an AGS were to start and run the generator for an extended period
of time in a confi ned area, a potentially fatal level of CO (Carbon Monoxide) could
accumulate.
Summary of Contents for Magnum Energy MS Series
Page 1: ...Pure Sine Wave Inverter Charger MS Series Owner s Manual...
Page 23: ...2016 Sensata Technologies Page 13 Installation Figure 2 5 MS Dimensions MS2000...
Page 43: ...2016 Sensata Technologies Page 33 Installation Figure 2 16 AC Wiring for MS2000 Models...
Page 44: ...Page 34 2016 Sensata Technologies Installation Figure 2 17 AC Wiring for MS2000 15B 20B Models...