background image

IMPOR

TANT:

 Read this manual before installation, it contains important safety, installation, 

and operating instructions. Save this manual and keep it in a safe place.

 

NOTE: This product is Listed to applicable UL Standards and requirements by Underwriters 

Laboratories Inc., File E100666.

Sensata Technologies is an ISO 9001:2008 Registered Company.

Sensata uses the following special notices to provide warning of possible safety related 

problems which could cause serious injury and to provide information to help prevent dam-

age to equipment.

DANGER indicates an imminently hazardous situation which, if not avoided will result 

in death or serious injury.

WARNING indicates a potentially hazardous situation which, if not avoided, could 

result in death or serious injury.

CAUTION indicates a potentially hazardous situation which, if not avoided, may result 

in minor or moderate injury.

CAUTION used without the safety alert symbol indicates a potentially hazardous situa-

tion which, if not avoided, may result in property damage.

NOTE is used to notify of installation, operation, or maintenance information that is 

important but not hazard related.

2

 

SAFETY INSTRUCTIONS

 Inverter Safety Instructions:

WARNING: Power Inverters produce hazardous voltages. To avoid risk of harm or fire, 

the unit must be properly installed.

WARNING: There are no user serviceable parts inside, do not remove the cover.

WARNING: Power Inverters should not be mounted in a location that may be exposed 

to rain or spray.

WARNING: Power Inverters should not be installed in a zero clearance enclosure.

WARNING Damage to the Power Inverter will occur if correct polarity is not observed 

when installing the inverter’s DC input cables.

WARNING: Damage to the Power Inverter will occur if an external AC power source is 

applied to the inverter’s AC hardwire output.

WARNING: Power Inverters contain a circuit breaker and capacitor that may produce a 

spark. Do not mount in a confined battery or gas compartment.

WARNING: Be sure the Power Inverter is turned OFF during installation.

Summary of Contents for 12/1200N

Page 1: ...DC to AC POWER INVERTERS Pure Sine Wave Output OWNER S MANUAL MODELS 12 1800N 12 2400N 12 3000N 12 3600N MODELS 12 800N 12 1200N 12 1500N...

Page 2: ...NG DIAGRAMS 6 Typical Wiring Diagram for 12 800N 12 1200N 12 1500N Typical Wiring Diagram for 12 800N 12 1200N 12 1500N 6 Typical Wiring Diagram for 12 8000N 12 2400N 12 3000N 12 3600N Typical Wiring...

Page 3: ...symbol indicates a potentially hazardous situa tion which if not avoided may result in property damage NOTE is used to notify of installation operation or maintenance information that is important but...

Page 4: ...the green LED Inverter will come on The AC power produced by the inverter comes from the energy stored in the battery bank through a sophisticated electronic inversion process A transformer a Metal O...

Page 5: ...r Models 12 1800N 12 2400N 12 3000N Inverter Model 12 3600N 4 NOTE The inverter mounting location should provide adequate ventilation and clearance to maintain room temperature during operation A mini...

Page 6: ...xt larger size cable Cable Recommendations 1 Use stranded copper cable 2 Use SGX cross linked polyurethane insulation type that complies with the high temperature insulation requirements 125 C of SAE...

Page 7: ...errupt GFCI protected unless the inverter has option A GFCI outlets should be installed at all appropriate locations per NEC 551 The GFCI outlet should be Leviton Type 7899 or N7899 20Amp 125VAC WIRIN...

Page 8: ...Typical Wiring Diagram for 12 1800N 12 2400N 12 3000N 12 3600N 7...

Page 9: ...8 Typical DC Cable Connections for 12 800N 12 1200N 12 1500N...

Page 10: ...Typical DC Cable Conn s for 12 1800N 12 2400N 12 3000N 12 3600N 9...

Page 11: ...No remote power on input to inverter Go to Troubleshooting Step 1 Inverter POWER ON indicator is on and work light not ON 1 Tripped inverter output circuit breaker 2 Tripped inverter Ground Fault Cir...

Page 12: ...ical assistance Step 2 LOW INPUT VOLTAGE indicator LED is ON NOTE Failures can be caused by one or more of the following a failed or under rated alternator and or failed alternator regulator inoperati...

Page 13: ...x 7 5 15 x 17 x 10 Weight Lbs 25 29 29 42 56 58 80 OTHER DESIGN FEATURES UNIT PROTECTION BATTERY PROTECTION High performance construction and coolong methods Microprocessor controlled Thermally contro...

Page 14: ...e qualifications indicated Sensata warrants to the original purchaser for use that the goods or any component thereof manufactured by Sensata will be free from defects in workmanship from the date of...

Page 15: ...14 Notes...

Page 16: ...ensions Inverters 4467 White Bear Parkway St Paul MN 55110 Phone 651 653 7000 800 553 6418 Fax 651 653 7600 888 439 3565 inverterinfo sensata com www dimensions sensata com Form No 122187 03 21 14 Sen...