background image

Web server

EN

Web server

In order to configure the WiCOS AP access point and with it the complete WiCOS
conference system, you have to call up the web server of the access point. For this,
you require a computer with network connection (RJ 45). For more information on
the web server, refer to the detailed instruction manual.

Use the supplied network cable (Cat5) to connect the network socket (RJ 45)
of the access point to your computer.

Make sure that your computer is set to the same address range as the access
point (IP range: 192.168.0.xxx, subnet mask: 255.255.255.0).

In the address box of the browser (e.g. Internet Explorer or Firefox), type the
IP address of the access point “192.168.0.10”. 
The web server appears and prompts for a password.

Accessories and spare parts

WiCOS AP specifications 

Factory default settings of the access point’s web server

IP address

192.168.0.10

Subnet mask

255.255.255.0

Password

123

Accessories and spare parts for the WiCOS conference system can be found
on our website at www.sennheiser.com.

Frequency response

150–15000 Hz

Frequency ranges

2.4 GHz; 5.1–5.8 GHz

Signal-to-noise ratio

> 70 dB(A)

Supply voltage

24 V 

Power consumption

6 W

Operating temperature

                  41

°

F

 to 

113

°

F

Dimensions

approx. 

10.24

9.05

 x 

1.5 in.

Weight

approx. 2

 lbs. 11.03 oz.

Color

RAL 7035

BB_WiCOS-AP.fm  Seite 10  Dienstag, 21. April 2009  3:01 15

4

Reviews: