MobileConnect Station network configuration
•
This port is used for the local administration interface and using it on the network ports may cause the
local interface to become inaccessible
•
To fix
→
unplug the LAN2/PoE/Stream port and perform a reset followed by a reboot
•
Alternatively change the IP address via the MobileConnect Manager
•
The local administration interface may become inaccessible
•
To access it again via LAN1
→
unplug the LAN2 and LAN3 cables
MobileConnect Manager web interface
•
This indicates there are interruptions in network connectivity
•
Contact us at
You configured the IP address 192.168.0.10 on the LAN2/PoE/Streaming port or
LAN3/Ctrl port.
You configured an IP address in the subnet 192.168.0.0 on the MCSv1 LAN2 or LAN3.
The MobileConnect Manager interface is showing the error message "Live updates are temporarily
interrupted" often.