HEV 70
03 / 94 – 9
NOTES:
No.
Measurement,
adjustment
Signal input
Preparations, settings
Test point
Desired value
Adjuster
Remarks
1
Current
consumption
AF signal generator to
J1 (R and L channel):
200 mVeff / 1 kHz
Switch S1 "ON"
volume control
R104.1 and R104.2 "cw";
DC ammeter
Input
current
210 - 230 mA
(minimum)
R128
LED D29 "red"
1.1
Operating voltage
as 1.
as 1.;
DC voltmeter
TP1
24 - 28 VDC
2
Reference voltage
as 1.
as 1.;
DC voltmeter
MP1
5.1 VDC
3
Converter
frequency
as 1.
as 2.;
Oscilloscope
MP2
> 60 kHz
please see
pattern on
page 7
4
Operating voltage
+ 600 V
as 1.
as 2.;
DC voltmeter
MP3
580 - 600 VDC
4.1
Operating voltage
+ 10 V
as 1.
as 2.;
DC voltmeter
MP4
10 VDC
4.2
Operating voltage
– 10 V
as 1.
as 2.;
DC voltmeter
MP5
– 10 VDC
4.3
Output stage
bias voltage
as 1.
as 2.;
DC voltmeter
MP6 (+R)
MP7 (–R)
MP8 (–L)
MP9 (+L)
300
±
15 VDC
5
Polarisation
voltage
as 1.
as 2.;
DC voltmeter
MP10
255 VDC
6
AF amplifier
as 1.
as 2.;
UPM 550 - 1 and
Oscilloscope
MP11 (R)
MP12 (L)
190 - 200 mVeff
6.1
AF amplifier
as 1.
as 2.;
UPM 550 - 1 and
Oscilloscope
MP13 (R)
MP14 (L)
190 - 200 mVeff
6.2
Output voltage
if outputs are clipping
decrease AF signal
generator voltage
down to 180 mVeff
as 2.;
UPM 550 - 1 and
Oscilloscope
MP15 (+R)
MP16 (–R)
MP17 (–L)
MP18 (+L)
180 - 200 Veff
Output voltage
is not clipping
7
THD
as 6.2.
as 2.;
UPM 550 - 1 and
Oscilloscope
MP15 (+R)
MP16 (–R)
MP17 (–L)
MP18 (+L)
k < 0.3 %
8
Frequency
response
AF signal generator:
60 mVeff / 1 kHz
as 2.;
set indicated value to
reference level, adjust
UPM 550 - 1 to 0 dB
(Uncal. - Adjuster)
MP15 (+R)
MP16 (–R)
MP17 (–L)
MP18 (+L)
U = 0 dB
LED D29
"green"
8.1
Frequency
response
Check frequency
response with
AF signal generator
from 20 Hz to 20 kHz
MP15 (+R)
MP16 (–R)
MP17 (–L)
MP18 (+L)
– 2 ... 0 dB
6. TEST AND ALIGNMENT INSTRUCTIONS
Download v. www.rainers-elektronikpage.de ; gescannt von Rainer Fredel