User Manual
Z-SG2 / Z-SG2-L
ALL RIGHTS RESERVED. NO PART OF THIS PUBLICATION MAY
BE REPRODUCED WITHOUT PRIOR PERMISSION.
www.seneca.it
Doc: MI-005370-EN
Rev. 6
Page 50
ADDRESS
(4x)
ADDRESS
OFFSET
REGISTER
DESCRIPTION
W/R
TYPE
40055
54
DENOISE FILTER
VALUE
It is possible to configure a
pre-determined filter level:
FILTER LEVEL
RESPONSE
TIME
[ms]
0
16
1
32
2
50
3
250
4
400
(default)
5
900
6
1800
7
“ADVANCED”
Dependent on the
configuration
The higher the filter level the
more stable (but slow) the
weight measurement will be.
A value other than 7 will
overwrite the advanced
parameters.
In the "Advanced" mode it will
be possible to act on the
individual parameters of the
ADVANCED MOVING
AVERAGE, ADVANCED
NOISE FILTER VARIATION,
ADVANCED NOISE FILTER
RESPONSE filter
ADVANCED ADC CHOPPER
RW** UNSIGNED
16 BIT