background image

MI00531-2-EN

INSTALLATION MANUAL

1/7

INSTALLATION MANUAL

SENECA s.r.l.; Via Austria, 26 – 35127 – PADOVA – ITALY; Tel.  +39.049.8705359  -  Fax +39.049.8706287

R-8AI-8DIDO

DOCUMENTATION

R-8AI-8DIDO-P

DOCUMENTATION

PRELIMINARY WARNINGS

The word 

WARNING

 preceded by the symbol 

 indicates conditions or actions that put the user’s safety at 

risk. The word 

ATTENTION

 preceded by the symbol 

 indicates conditions or actions that might damage the 

instrument or the connected equipment. The warranty shall become null and void in the event of improper use or 

tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if 

the instructions contained in this manual are not followed.

WARNING

: The full content of this manual must be read before any operation.

The module must only be used by qualified electricians.

Specific documentation is available using the QR-CODE shown on page 1.

Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling).

The symbol on the product or its packaging shows the product must be surrendered to a collection centre 

authorized to recycle electrical and electronic waste.

The module must be repaired and damaged parts replaced by the Manufacturer.

The product is sensitive to electrostatic discharges. Take appropriate measures during any operation.

CONTACT INFORMATION

Technical support

[email protected]

Product information

[email protected]

This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised.

The content of this document corresponds to the described products and technologies.

Stated data may be modified or supplemented for technical and/or sales purposes.

R-8AI-8DIDO

R-8AI-8DIDO-P

Summary of Contents for R-8AI-8DIDO

Page 1: ...ny operation The module must only be used by qualified electricians Specific documentation is available using the QR CODE shown on page 1 Electrical and electronic waste disposal applicable in the Eur...

Page 2: ...s set Flashing Waiting for the IP address from the DHCP COM R 8AI 8DIDO P version only On Verification of RS485 connection Flashing Data packet transmission over RS485 FAIL On Digital output in FAIL O...

Page 3: ...IDO version only 2 Ethernet with LAN fault bypass function 100 base T on RJ45 1 RS485 port on terminals R 8AI 8DIDO version only AUXILIARY VOLTAGE OUTPUT Max voltage current 12 Vdc 20 mA DIGITAL INPUT...

Page 4: ...ome devices may be inverted ANALOGUE INPUTS The device has 8 analogue inputs that can be configured via DIP SDWITCH CURRENT mA Transmitter active VOLTAGE V 30V THERMOCOUPLE Tc mV B A C mA 40 43 60 63...

Page 5: ...ERA ISOTERMA RAME RAME RAME TC TC ANALOGUE INPUTS Range Resolution Impedance Precision Temperature drift Ext current Voltage V 30 30 Vdc 1 mV 200 kohm 0 1 f s 100 ppm Voltage mV 120 120 mV 4 uV 10 Moh...

Page 6: ...vice have the following functions DIP SWITCH positions DIP SWITCH SW1 AND SW2 ANALOGUE INPUT OUTPUT CONFIGURATION SW3 DIP SWITCH DEFAULT SETTINGS SETTING THE DIP SWITCHES SW1 SW2 1 2 3 4 1 2 3 4 AI1 A...

Page 7: ...s not interrupted and the devices downstream of the switched off one will still be accessible This function has a limited duration the connection remains active for a few days typically 4 The fault by...

Reviews: