background image

- 10 -

 

12/2019

 Copyright © 2019, Fast ČR, a.s.

3. Flap angle setting function

 ■

Button 

D7

 serves to start or stop the motion of the flap. The flap can be set to 6 

different angles. A different angle is set each time the button is pressed. Holding 

down button 

D7

 activates the automatic motion of the flap.

4. SHORTCUT function

 ■

This function serves to restore the current settings or to restore the previous settings.

 ■

While the remote control is turned on, press the button 

SHORTCUT D11

 to 

automatically switch to the previous settings, including the operating mode, set 

temperatures, fan speed and the sleep function, if it was activated.

 ■

When the button 

SHORTCUT D11

 is held down for approximately 2 seconds, the 

original settings will automatically be restored, including the operating mode, set 

temperatures, fan speed and the sleep function, if it was activated.

5. Follow Me function

The remote control serves as a remote thermostat allowing for the precise temperature 

control at its location.

To activate the Follow Me feature, point the remote control towards the unit and press 

the FOLLOW ME 

D12

. The remote control will send this signal to the air conditioner 

until press the FOLLOW ME 

D12

 again. If the unit does not receive the Follow Me signal 

during any 7 minutes interval, the unit will exit the Follow Me mode.

Note

:

This feature can be activated from the remote control only. This feature 

is unavailable under FAN or DRY mode.

MAINTENANCE AND CLEANING

 ■

Before cleaning the portable air conditioner, turn it off and wait a few minutes, and 

then pull the power cord out of the power socket.

Cleaning the air filters

 ■

When the portable air conditioner is used regularly, it is necessary to clean the air 

filters (

A6

 and 

A10

) located behind the protective grille of the top and bottom air 

inlets 

A7

 and 

A11

 at least once every 14 days to prevent the fan from being clogged 

by dust.

 ■

Carefully remove the protective grilles and remove the filters (

A6

 and 

A10

). To 

remove the dust, use a  vacuum cleaner. In the event of greater soiling, wash the 

filters (

A6

 and 

A10

) in a  solution of lukewarm water (max. 40  °C) and neutral 

detergent. Then thoroughly rinse under running water and allow to dry naturally. Do 

not dry it in a clothes dryer or in direct sunlight. Once the filters (

A6

 and 

A10

) are dry, 

you can install them back in their place.

Note: 

Do not use the portable air conditioner without the air filters (

A6

 and 

A10

) properly installed and do not use it with wet or damp air filters 

(

A6

 and 

A10

).

Condensate tank

 ■

The condensate tank must be drained immediately when the error message P1 

appears on the display 

C12

 and also before this appliance is stored in order to 

prevent the formation of moulds.

Cleaning the outer case

 ■

To clean the outer case, use a soft wiping cloth dipped in a solution of lukewarm 

water and neutral detergent. Then wipe the surface dry.

 ■

When cleaning it, do not spray the portable air conditioner with water or any other 

liquid, do not pour water on it or submerge it in water or in any other liquid.

 ■

Do not use abrasive cleaning products, solvents, petrol, etc. for cleaning.

Note:

In households with pets, it is necessary to wipe the grille regularly to 

prevent it from becoming clogged by animal fur.

Storing the portable air conditioner

 ■

In order to dry it and to prevent the formation of moulds, leave the portable air 

conditioner running in a warm room in the fan mode for approximately 12 hours.

 ■

Disconnect the flexible hose 

B3

 and store it in a  safe place out of the reach of 

children.

 ■

Drain all the condensate from the water tank – see chapter “

Condensate drain 

outlet

”.

 ■

Clean the air filters (

A6

 and 

A10

) and reinstall them. Wipe the outer case of the 

portable air conditioner. Remove the batteries from the remote control.

 ■

Store the air conditioner in a cool, dry and dark location.

Condensate drain outlet

If the water level inside the water tank reaches a predetermined level, the portable air 

conditioner will show the error message P1 on the display 

C12

. In order to drain the 

condensate from the air conditioner, proceed as follows: 

1. Disconnect the power plug from the power socket.

2.  Carefully re-locate the portable air conditioner to a location where the water may be 

drained.

3. Underneath the drain outlet 

A16

, place a container into which the condensate will 

flow. Carefully remove the plug of the drain outlet 

A16

. Connect the drain hose 

B7

 

and allow the condensate to flow out.

4. Once the water tank is empty (condensate has stopped flowing), disconnect the 

drain hose 

B7

 and put the plug back into the drain outlet 

A16

.

5.  Insert the power plug into a power socket and turn on the portable air conditioner.

   If you need to ensure the condensate to be continuously drained from the portable 

air conditioner, it is possible to connect the drain hose 

B7

 to a waste water drain. 

Proceed as follows:

1. Disconnect the power plug from the power socket.

2.  Remove the plug of the drain outlet 

A16

. Connect the drain hose 

B7

. If the length of 

the drain hose 

B7

 is insufficient, then it is necessary to purchase a longer hose of the 

same type. Never extend the length of the drain hose 

B7

 using extensions.

3. Connect the end of the drain hose 

B7

 to the waste water drain.

4. Insert the power plug into a power socket and turn on the portable air conditioner.

Note:

The drain hose 

B7

 should be installed at the same height or lower 

than the top drain outlet 

A16

. Otherwise, the condensate will not be 

properly drained from the water tank.

Putting into operation again

 ■

Check that the power cord and plug are not damaged and that the air filters are 

clean. Insert a new set of batteries into the remote control. Proceed according to 

the instructions in section “Inserting and replacing batteries”. Install the portable 

air conditioner according to the instructions contained in the preceding part of this 

user’s manual “Installation”.

TROUBLESHOOTING

Before contacting an authorised service centre, please check the appliance according 

to the following instructions:

Problem

Cause

Solution

The portable air 

conditioner does not 

turn on when the 

ON/OFF button is 

pressed.

Error message P1.

The condensate tank is 

full. Turn off the portable 

air conditioner and drain 

the condensate from the 

condensate tank according 

to the instructions in the 

section "

Condensate drain 

outlet

" in the preceding 

part of this user's manual.

In the cooling mode: the 

temperature in the room is 

lower than the set temperature.

Adjust the set temperature.

The portable air 

conditioner does not 

cool sufficiently.

The air filter is clogged with 

dust and animal fur.

Turn off the portable air 

conditioner and clean out 

the filter according to the 

instructions in chapter 

"

Maintenance and 

cleaning

".

The flexible air exhaust hose is 

not connected or it is clogged.

Turn off the portable air 

conditioner and check 

the hose connection, or 

if necessary, remove any 

material inside the hose.

There is an insufficient amount 

of refrigerant gas in the 

portable air conditioner.

Contact an authorised 

service centre.

You set a temperature that is 

too high.

Lower the set temperature.

Windows or doors are open.

Close any windows or doors.

The room is too large.

Check recommended 

room area.

A heat source is turned on in 

the room.

Turn off the heat source.

The portable air 

conditioner is too 

noisy and vibrates 

too much.

The portable air conditioner is 

located on an uneven surface.

Move the portable air 

conditioner to an even and 

level surface.

The air filter is clogged with 

dust and animal fur.

Turn off the portable air 

conditioner and clean out 

the filter according to the 

instructions in chapter 

"

Maintenance and 

cleaning

".

The portable air 

conditioner is 

emitting gurgling 

sounds.

The noise is caused by the 

movement of the refrigerant 

inside the portable air 

conditioner.

This is normal.

Note: 

In the event that one of the aforementioned faults occurs, turn off the 

portable air conditioner and check for the cause of the fault. Turn it on 

again, and if the fault reoccurs, turn it off, disconnect the power cord 

from the power socket and contact the manufacturer, an authorised 

service centre or a  person with relevant qualifications and have the 

unit repaired.

Summary of Contents for SAC MT1230C

Page 1: ...12 2019 1 Copyright 2019 Fast R a s EN Portable air conditioner Translation of the original manual SAC MT1230C SAC MT1231C...

Page 2: ...ct the appliance only to a properly grounded socket The power socket must be freely accessible so that it is possible to quickly disconnect the power cord from the power source if necessary The applia...

Page 3: ...lt in a water leak injury by electrical shock or fire To prevent the risk of fire or injury by electrical shock do not use this appliance with a timer or any another similar device that could spontane...

Page 4: ...perated or stored must prevent the accumulation of such leaked refrigerants that could be the cause of explosion or fire as a result of the refrigerant igniting following the start up of electrical he...

Page 5: ...12 2019 5 Copyright 2019 Fast R a s SAC MT1230C SAC MT1231C A 1 2 6 3 7 4 8 9 10 11 12 13 5 14 15 16...

Page 6: ...12 2019 6 Copyright 2019 Fast R a s B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 C 1 2 3 4 5 6 7 8 9 10 14 15 11 13 12...

Page 7: ...12 2019 7 Copyright 2019 Fast R a s ON OFF TEMP SHORT CUT TIMER ON TIMER OFF MODE FAN SLEEP FOLLOW SWING LED ME 1 2 3 4 6 5 7 D 11 10 9 8 12...

Page 8: ...Nevertheless for certain types of slide windows it may be necessary to modify the installation procedure described below Open the sliding window sash and stick on the gasket seal B8 along the entire...

Page 9: ...nal may not be transmitted Note Do not combine old and new batteries or batteries of various types Never put the batteries in a fire short circuit them or damage them in any way Dispose of them ecolog...

Page 10: ...y C12 In order to drain the condensate from the air conditioner proceed as follows 1 Disconnect the power plug from the power socket 2 Carefully re locate the portable air conditioner to a location wh...

Page 11: ...uced in the event that it is used outside the above described operating temperature range We reserve the right to change text and technical specifications INSTRUCTIONS AND INFORMATION REGARDING THE DI...

Reviews: