background image

- 9 -

 

12/2019

 Copyright © 2019, Fast ČR, a.s.

3. Dehumidification mode

 ■

Make sure that the flexible hose 

B3

 is disconnected from the air conditioner. 

Repeatedly press button 

MODE C3

 until the dehumidification indicator   is lit. It 

is not possible to set the temperature or fan speed in this mode. The fan speed is 

automatically set.

4. Automatic mode

 ■

In the automatic mode, the portable air conditioner will automatically set 

the operating mode (cooling / fan / dehumidification) depending on the set 

temperature and the temperature in the room. The portable air conditioner will 

automatically control the temperature in the room based on the temperature that 

you set. It is not possible to set the fan speed in the automatic mode.

 ■

Repeatedly press button 

MODE C3

 until the automatic mode indicator 

 is lit. In 

the automatic mode both the automatic mode indicatoras well as the indicator of 

the selected operating mode will be lit.

FUNCTIONS OF THE PORTABLE AIR CONDITIONER

1. Timer functions

 ■

While the portable air conditioner is turned on, press the 

Timer C2

 button. You will 

enter the automatic shut-off mode and “TIMER OFF” will be shown on the display 

C12

. Use the 

 / 

+

 buttons to set the desired duration. Press the 

TIMER C2

 button 

within 5 seconds to enter the automatic start mode. “TIMER ON” will be shown on the 

display 

C12

. Use the 

 / 

+

 buttons to set the desired duration.

 ■

While the portable air conditioner is turned off, press the 

TIMER C2

 button and 

use the 

 / 

+

 buttons to set the desired duration. Press the 

TIMER C2

 button within 

5 seconds to enter the automatic shut-off mode. Use the 

 / 

+

 buttons to set the 

desired duration.

 ■

The desired start / shut-off duration can be set in 30-minute increments (up to 10 

hours) and in 1-hour increments (up to 24 hours). The portable air conditioner will 

automatically countdown the set duration.

 ■

The portable air conditioner will automatically switch to the previously set 

temperature if no button is pressed within 5 seconds.

 ■

If you need to turn off the timer, turn the portable air conditioner on or off, or 

alternatively set the timer to 0 hours.

2. Sleep function

 ■

The sleep function is used to reduce overnight power consumption.

 ■

Press the 

SLEEP C7

 button. The temperature will increase by 1  °C within 30 minutes. 

Within the next 30 minutes the temperature will increase by another 1  °C. The 

portable air conditioner will maintain this new temperature for a further 7 hours. The 

temperature setting will then return to the initially set temperature and the sleep 

function will be automatically cancelled.

Note: 

This function cannot be set in the fan and dehumidification modes.

3. Flap swing function

 ■

Press the 

SWING C1

 button to automatically start the swinging motion of the flap. 

While the flap is swinging, press the 

SWING C1

 button again to stop the flap at 

a certain angle.

Note: 

When the portable air conditioner stops its operation, it will not be 

possible to start it again for approximately 3 minutes. This is a standard 

protection feature. It can be put back into operation after 3 minutes.

B. REMOTE CONTROL

Inserting and replacing batteries

 ■

Slide out the battery compartment cover, which is located on the rear side of the 

remote control. Place two AAA/LR03 (2x 1.5V) alkaline batteries into the battery 

compartment and close the cover.

 ■

When inserting the batteries ensure the correct polarity as shown in the battery 

compartment.

 ■

When replacing the batteries, always use batteries of the same type, never combine 

old and new batteries or batteries of various types.

Note:

Removing the batteries from the remote control will delete all the 

settings. After new batteries are inserted the default remote control 

settings as programmed by the manufacturer will be renewed.

If you will not be using the remote control for longer than 2 months, 

remove the batteries.

Using the remote control

 ■

For the remote control to work correctly, ensure that the maximum distance of the 

remote control from the portable air conditioner is not greater than 7 m and that 

there is no obstacle between the remote control and the portable air conditioner 

that could prevent the transmission of the signal.

 ■

Point the remote control directly at the portable air conditioner. The transmission of 

the signal is confirmed by a short sound signal.

 ■

Do not expose the remote control to direct sunlight or high temperatures. Otherwise 

the signal may not be transmitted.

Note:

Do not combine old and new batteries or batteries of various types. 

Never put the batteries in a fire, short circuit them or damage them in 

any way. Dispose of them ecologically at the end of their lifetime. Never 

throw batteries out with communal waste.

Turning the portable air conditioner on and off

To turn on the portable air conditioner, press button 

D2

 once. Press button 

D2

 again to 

turn the portable air conditioner off.

OPERATING MODES

1. Cooling mode

 ■

Repeatedly press button 

MODE D3

 until the cooling indicator 

 is lit. Using the 

▲/▼

 buttons, set the desired temperature. You can set the temperature in the range 

from 17 to 30 °C.

 ■

Repeatedly press the 

FAN

 

D5

 button to set the fan speed: high speed – medium 

speed – low speed – automatic speed.

 ■

Press button 

D2

 to turn the portable air conditioner on in the cooling mode.

2. Fan mode

 ■

Repeatedly press button 

MODE

 

D3

 until the fan mode indicator 

 is lit.

 ■

Repeatedly press the 

FAN

 

D5

 button to set the fan speed: high speed – medium 

speed – low speed – automatic speed.

 ■

Press button 

D2

 to turn the portable air conditioner on in the fan mode.

 

Note

: In the fan mode, it is not possible to set the temperature, therefore no 

temperature information will be shown on the display 

D1

.

3. Dehumidification mode

 ■

Repeatedly press button 

MODE

 

D3

 until the dehumidification indicator   is lit. 

 ■

It is not possible to set the temperature or fan speed in this mode. The fan speed is 

automatically set.

 ■

Press button 

D2

 to turn the portable air conditioner on in the dehumidification 

mode.

4. Automatic mode

 ■

If you select an automatic mode, the portable air conditioner will automatically 

select an operating mode based on the temperature in the room.

 ■

Repeatedly press button 

MODE

 

D3

 until the automatic mode indicator 

 is lit.

 ■

Press button 

D2

 to turn the portable air conditioner on in the automatic mode.

FUNCTIONS OF THE PORTABLE AIR CONDITIONER

1. Automatic start and shut-off function

Automatic start

 ■

The automatic start function makes it possible to set a time after which the portable 

air conditioner will start automatically.

 ■

Press the 

TIMER ON D10

 button. The last set time and “h” (hours) will start flashing 

on the display 

D1

.

 ■

Repeatedly press the 

TIMER ON D10

 button and set the time in hours after which 

the portable air conditioner will turn on automatically. The digits on the display 

D1

 

represent the time in hours.

 ■

Wait approximately 2 seconds and the automatic start function will be activated. The 

set temperature is then shown on the then display 

D1

.

Automatic shut-off

 ■

The automatic shut-off function makes it possible to set a  time after which the 

portable air conditioner will shut off automatically.

 ■

Press the 

TIMER OFF D9

 button. The last set time and “h” (hours) will start flashing 

on the display 

D1

.

 ■

Repeatedly press the 

TIMER OFF D9

 button and set the time in hours after which 

the portable air conditioner will turn off automatically. The digits on the display 

D1

 

represent the time in hours.

 ■

Wait approximately 2 seconds and the automatic start function will be activated. The 

set temperature is then shown on the then display 

D1

.

Note:

The automatic shut-off or start time can be set in the range between 30 

minutes and 24 hours (set in 30 minute intervals until 10 hours, and one 

hour intervals until 24 hours).

In the event that you need to cancel the automatic shut-off or start function, set the 

time to “0.0”.

Setting automatic start and shut-off at the same time

 ■

When setting the automatic start and shut-off, it is necessary to take into 

consideration the current time since the start and shut-off time will be counted 

down from it.

 ■

Press the 

TIMER ON D10

 button. The last set time and “h” (hours) will start flashing 

on the display 

D1

. Repeatedly press the 

TIMER ON D10

 button and set the time 

in hours after which the portable air conditioner will turn on automatically. Wait 

approximately 3 seconds and the automatic start function will be activated.

 ■

Now press the 

TIMER OFF D9

 button. The last set time and “h” (hours) will start 

flashing on the display 

D1

. Repeatedly press the 

TIMER OFF D9

 button and set the 

time in hours after which the portable air conditioner will turn off automatically. Wait 

approximately 3 seconds and the automatic start function will be activated.

2. Sleep function

The sleep function is used to reduce overnight power consumption.

Press button 

D6

, and the 

 symbol will appear on the display 

D1

. The portable air 

conditioner will run in the last selected mode, however, this function cannot be set in 

the fan and dehumidification modes.

Summary of Contents for SAC MT1230C

Page 1: ...12 2019 1 Copyright 2019 Fast R a s EN Portable air conditioner Translation of the original manual SAC MT1230C SAC MT1231C...

Page 2: ...ct the appliance only to a properly grounded socket The power socket must be freely accessible so that it is possible to quickly disconnect the power cord from the power source if necessary The applia...

Page 3: ...lt in a water leak injury by electrical shock or fire To prevent the risk of fire or injury by electrical shock do not use this appliance with a timer or any another similar device that could spontane...

Page 4: ...perated or stored must prevent the accumulation of such leaked refrigerants that could be the cause of explosion or fire as a result of the refrigerant igniting following the start up of electrical he...

Page 5: ...12 2019 5 Copyright 2019 Fast R a s SAC MT1230C SAC MT1231C A 1 2 6 3 7 4 8 9 10 11 12 13 5 14 15 16...

Page 6: ...12 2019 6 Copyright 2019 Fast R a s B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 C 1 2 3 4 5 6 7 8 9 10 14 15 11 13 12...

Page 7: ...12 2019 7 Copyright 2019 Fast R a s ON OFF TEMP SHORT CUT TIMER ON TIMER OFF MODE FAN SLEEP FOLLOW SWING LED ME 1 2 3 4 6 5 7 D 11 10 9 8 12...

Page 8: ...Nevertheless for certain types of slide windows it may be necessary to modify the installation procedure described below Open the sliding window sash and stick on the gasket seal B8 along the entire...

Page 9: ...nal may not be transmitted Note Do not combine old and new batteries or batteries of various types Never put the batteries in a fire short circuit them or damage them in any way Dispose of them ecolog...

Page 10: ...y C12 In order to drain the condensate from the air conditioner proceed as follows 1 Disconnect the power plug from the power socket 2 Carefully re locate the portable air conditioner to a location wh...

Page 11: ...uced in the event that it is used outside the above described operating temperature range We reserve the right to change text and technical specifications INSTRUCTIONS AND INFORMATION REGARDING THE DI...

Reviews: