Connecting to a Building’s Electrical System
Connections for standby power to a building’s electrical system must be made by a qualified electrician. The
connection must isolate the generator power from utility power, and must comply with all applicable laws and
electrical codes.
Generator Location Generator Clearance
WARNING
Running generator gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide
will cause nausea, fainting or death.
Operate generator ONLY outdoors.
Keep exhaust gas from entering a
confined area through windows, doors, ventilation intakes or other openings.
DO NOT operate generator
inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).
The generator must be at least 2m (5 ft.) from structures having combustible walls and/or other combustible
materials. Leave at least lm (3 ft.) all around generator including overhead, for adequate cooling, maintenance
and servicing. Place generator in a well ventilated area, which will allow for removal deadly exhaust gas. DO
NOT place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially
occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes or other
openings that can allow exhaust gas to collect in a confined area (Figure 2).Prevailing winds and air currents
should be taken into consideration when positioning generator.
WARNING Generator produces powerful voltage. Failure to isolate generator from power utility can result in
death or injury to electric utility workers due to backfeed of electrical energy.
When using generator for
backup power, notify utility company. Use approved transfer equipment to isolate generator from electric
utility.
Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal
decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords
which are worn, frayed, bare or otherwise damaged.
DO NOT operate generator in the rain.
DO NOT handle
generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.
DO NOT
allow unqualified persons or children to operate or service generator.
Italia Star Com Due S.R.L.
www.italiastar.ro
004/021.433.03.27
76
Summary of Contents for SC13000ATS
Page 3: ...Italia Star Com Due S R L www italiastar ro info italiastar ro 004 021 433 03 27 3...
Page 41: ...Italia Star Com Due S R L www italiastar ro info italiastar ro 004 021 433 03 27 41...
Page 49: ...Italia Star Com Due S R L www italiastar ro info italiastar ro 004 021 433 03 27 ATS 49...
Page 50: ...Italia Star Com Due S R L www italiastar ro info italiastar ro 004 021 433 03 27 50...
Page 74: ...Italia Star Com Due S R L www italiastar ro info italiastar ro 004 021 433 03 27 74...