58
ProBee-ZE20S Series User Guide Rev.0.1
available remote command by “AT+REMOTE<CR>”.
Execute AT+REMOTE=<addr>,<cmd>?<CR> AT+REMOTE=<addr>,<cmd>=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
7.8 UART
7.8.1 AT+BAUDRATE
or
AT+UB
Description
Get/Set the serial port speed for communication between the module serial port and
host.
Execute AT+BAUDRATE?<CR>
AT+BAUDRATE=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default 9600
Range
300 - 230400
7.8.2 AT+DATABIT
or
AT+UD
Description
Get/Set the serial data bit setting on the module.
Execute AT+DATABIT?<CR>
AT+DATABIT=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default 8
Range
7 - 8
7.8.3 AT+PARITY
or
AT+UP
Description
Get/Set the serial parity setting on the module.
Execute AT+PARITY?<CR>
AT+PARITY=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default 0
Range
0 - 2
7.8.4 AT+STOPBIT
or
AT+US
Description
Get/Set the serial stop bit setting on the module.
Execute AT+STOPBIT?<CR>
AT+STOPBIT=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default 1
Range
1 - 2
Summary of Contents for ProBee-ZE20S Series
Page 76: ...76 ProBee ZE20S Series User Guide Rev 0 1 10 Pin Assignments Figure 10 1 Pin Assignments...
Page 79: ...79 ProBee ZE20S Series User Guide Rev 0 1 Figure 11 2 ZE20SDC Mechanical Drawings...
Page 80: ...80 ProBee ZE20S Series User Guide Rev 0 1 Figure 11 3 ZE20SDS Mechanical Drawings...
Page 81: ...81 ProBee ZE20S Series User Guide Rev 0 1 Figure 11 4 ZE20SSU Mechanical Drawings...
Page 82: ...82 ProBee ZE20S Series User Guide Rev 0 1 Figure 11 5 ZE20SSC Mechanical Drawings...