
45
S11=1, Parani-ESD allows for the escape sequence charactesr. Whenever it is needed, the Connect
status can be changed to Standby.
C.7. S12: Clear Data Buffer When Disconnected (default 0)
S12=0, Parani-ESD does not clear the data buffer received from host system when disconnected.
S12=1, Parani-ESD clears the data buffer when disconnected.
C.8. S13: Enable DCD Signal (default 1)
S13=0, DCD signal off
S13=1, DCD signal on
C.9. S14: Enable DTR Transfer (default 1)
S14=0, DTR/DSR signal is transferred in a loop-back fashion..
S14=1, DTR signal is transferred to DSR of remote device.
C.10. S15: Enable Disconnect by DTR (default 0)
S15=0, DTR signal cannot release the connection.
S15=1, The Bluetooth connection can be released when DTR signal is off.
This value decides whether Bluetooth connection is released when DTR signal drops or not. If this
value is 1, you can use DTR signal in order to disconnect Bluetooth connection.
C.11. S22: Faster Connection (default 3)
S22=0, none
S22=1, page scan
S22=2, inquiry scan
S22=3, page/inquiry scan
Connecting time is average 1.5sec faster than normal mode.
C.12. S23: Intercharacter Timeout Setting (default 0)
S23=0 : Not used
S23=1 : 1 x S26
S23=2 : 10 x S26
S23=3 : 100 x S26
C.13. S24: Maximum Number of Inquiry Result (default 10)
The maximum number of inquiry list can be controlled. This value is up to 15.
C.14. S26: Intercharacter Timeout (default 0)
S23=1 x S26=50 : Timeout-> 50msec
S23=2 x S26=50 : Timeout-> 500msec
S23=3 x S26=3 : Timeout-> 300msec
Inter Character Time Out
* Optimal Value(S23 x S26)
50ms
180
100ms
235
200ms
340