Model SSD1-HS
508.366.1488 | semshred.com Page 6
of 23
4 – Installation
4.1
Power Requirements
FOR 110-120 VOLT/1-Phase/60HZ/1 HP
This machine has been supplied with a power cord and male plug for 30 amp service.
The male plug is a NEMA # L5-30P and requires a female connection as noted below, to be installed by
the customer.
Ref: NEMA # L5-30R.
FOR 220 VOLT/1-Phase/50HZ/1 HP
Note to Installer:
This machine has been supplied with a power cord for 20 amp service.
Note: Any oversea shipments at 220 Volt/1-Phase/50HZ must supply their own plug unless otherwise
specified at time of the order.
FOR 220 VOLT /1-Phase/50HZ/1 HP with 2 power cords
This machine has been supplied with two separate power cords for 13 Amp service. Be sure that both
cords are plugged into dedicated outlets.
Alternative Options:
•
Replace plug with customer supplied substitute while maintaining proper amperage ratings. This
must be done by a licensed electrician while observing local electrical codes.
•
This machine can be hardwired to a safety disconnect for permanent installations. This must be
done by a licensed electrician while observing local electrical codes.
4.2
Resetting Overloads
In the event of a voltage or amperage spike, one or both of the overloads on the electrical panel will trip
in order to prevent damage to the unit. This will cause the unit to shut down immediately, on both
single and double power cord units.
•
De-energize the unit using proper LOTO procedures.
•
Open the electrical panel cover on the back of the unit on the vacuum side. Requires Philips
head screwdriver, 5/32” or 9/64” Allen wrench.
•
Reset any tripped overloads or safety disconnects. Tripped overload will point sideways.
•
Plug in the unit to test if it is on and replace the electrical panel cover.