iveo initial operation/Setting by radio
6.1.2. Manual setup-mode, deletion and manual setting of the end positions
¨
in operation bottom position, top stop/release
When the movement is interrupted once, the system is in manual setup-mode. The
drive will only find the upper end limit automatically.
Important:
A limit stop for the upper end limit is necessary!
First the lower end limit has to be run-up to. From there move against the upper limit
stop
without
interruption, until the motor is automatically switched off.
Caution!
Only connect the radio motor that you wish to program to the mains. It is not possible
to program more than one motor at the same time.
Setting with
transmitter
Drive
Connect to power.
Press the
UP
and
DOWN
buttons at the transmitter at the
same time. The transmitter is temporarily programmed into
the motor.
6 s
Press the
STOP
button of the transmitter for 6 seconds.
or
Move the motor to the
lower
end position with the
UP
or
DOWN
button.
3 s
Press the
STOP
button of the transmitter for 3 seconds.
The correct rotation direction assignment will be carried out
at the end of the end position setting.
or
Move the drive with the
UP
or
DOWN
button against the
upper
limit stop. The motor
stops automatically
and
relieves shortly.
1 s
Press the
PROG
button at the transmitter.
The transmitter is now permanently programmed.