iveo initial operation/Setting by radio
First press the
STOP
button and then the
UP
and
DOWN
buttons as well. Keep all three
buttons pressed for 9 seconds, in order to start the group separation (wait until the
transmitter control light flashes three times). The motor indicates activation of group
separation by a short run. Then each motor will move randomly for 3 seconds within a
period of about 2 minutes. Within the 3-second time slot, stop the movement of the
motor using the
STOP
button on the transmitter to be programmed. Then the transmit-
ter is programmed, and the motor has left the group separation mode.
Every motor moves randomly only for
3 seconds within about 2 minutes.
The motor in question must be
stopped by the selected transmitter
during the movement.
If the motors are still moving together, repeat the procedure for the motors affected.
If you did not programm a transmitter through the
STOP
button and no other trans-
mitter is programmed, you may programm this transmitter again by pressing the
UP
and
DOWN
buttons at the same time and then pressing the
PROG
button.
6.9. Changing the radio system to commeo
To change the radio system of a motor with iveo transmitters, first set the motor to
service mode and then select the motor using a commeo transmitter by pressing the
SELECT
button for 3 seconds. When the motor has been selected, all iveo transmitters
have been re-programmed.
➧
➧
Fuse/Hirschmann plug
3 s
3 s
3 s
9 s
Window 1
Transmitter 1
3 s
Window 2
Transmitter 2
3 s
Window 3
Transmitter 3
3 s
➧
Fuse/Hirschmann plug
3 s
3 s
3 s
3 s
Summary of Contents for SE Plus-RC Series
Page 35: ...D D 35 Notizen...
Page 69: ...GB GB 69 Notes...
Page 103: ...F F 103 Notices...
Page 137: ...NL NL 137 Notities...
Page 171: ...PL 171 PL Notatki...