TRBL
SHTG
Troubleshooting
9-7
6C13G11
NOTE:
•
Before troubleshooting the outboard motor, check the mounting and rigging of the outboard motor.
Also, make sure that the specified fuel has been used and that the battery is fully charged.
•
To diagnose a mechanical malfunction, use the troubleshooting charts for each trouble located in
this chapter. Also, when checking and maintaining the outboard motor, see Chapters 3
–
8 for safe
maintenance procedures.
•
To diagnose a sensor or switch malfunction, use the diagnostic flash indicator to determine the
cause.
Power unit
9
Symptom 1: Engine does not start or starting the engine is difficult.
Starting system
Check that the gear shift is in
the neutral position.
No
Continued on next page.
Is the gear shift
in neutral?
Check the starter motor opera-
tion.
Set it to the neutral position.
Check the ignition system or the
fuel system.
No
Yes
Good operating
condition?
Check the battery lead connec-
tions and the starter motor posi-
tive terminal for damage and
check that the ground lead bolt
is not loose or that it has not
come off. Check for blown
fuses.
Yes
Summary of Contents for Dorado 50 EFI
Page 1: ...Dorado 60 EFI Dorado 50 EFI SERVICE MANUAL ...
Page 4: ......
Page 48: ...SPEC Specifications 2 25 6C13G11 MEMO ...
Page 165: ...6C13G11 6 22 1 2 3 4 5 6 7 8 9 Shimming 6 Drive shaft and lower case Shimming ...
Page 190: ...LOWR Lower unit 6 47 6C13G11 Shimming FT50 FT60 6 ...
Page 195: ...6C13G11 6 52 1 2 3 4 5 6 7 8 9 MEMO Backlash FT50 FT60 ...
Page 221: ...6C13G11 7 24 1 2 3 4 5 6 7 8 9 Steering arm ...
Page 270: ...ELEC Electrical systems 8 21 6C13G11 MEMO ...
Page 299: ...6C13G11 i 5 1 2 3 4 5 6 7 8 9 Index MEMO ...
Page 301: ......
Page 302: ......