ELEC
Electrical systems
–
+
8-15
6C13G11
Starting system
8
Checking the fuses
1.
Check the fuses for continuity. Replace if
there is no continuity.
Checking the starter relay
1.
Connect the digital circuit tester leads to
the starter relay terminals.
2.
Connect the positive battery terminal to
the brown (Br) lead.
3.
Connect the negative battery terminal to
the black (B) lead.
4.
Check for continuity between the starter
relay terminals. Replace if there is no
continuity.
5.
Check that there is no continuity between
the starter relay terminals after discon-
necting a battery terminal from the brown
(Br) or black (B) lead. Replace if there is
continuity.
S60V8265
Br
B
Summary of Contents for Dorado 50 EFI
Page 1: ...Dorado 60 EFI Dorado 50 EFI SERVICE MANUAL ...
Page 4: ......
Page 48: ...SPEC Specifications 2 25 6C13G11 MEMO ...
Page 165: ...6C13G11 6 22 1 2 3 4 5 6 7 8 9 Shimming 6 Drive shaft and lower case Shimming ...
Page 190: ...LOWR Lower unit 6 47 6C13G11 Shimming FT50 FT60 6 ...
Page 195: ...6C13G11 6 52 1 2 3 4 5 6 7 8 9 MEMO Backlash FT50 FT60 ...
Page 221: ...6C13G11 7 24 1 2 3 4 5 6 7 8 9 Steering arm ...
Page 270: ...ELEC Electrical systems 8 21 6C13G11 MEMO ...
Page 299: ...6C13G11 i 5 1 2 3 4 5 6 7 8 9 Index MEMO ...
Page 301: ......
Page 302: ......