background image

Pg. 4

YES

NO

Installation instructions

"Thesis plus" is an electronically controlled thermostat compatible with the

heating element types showed in the picture below.

IMPORTANT

:

Pay attention to the maximal length of the

19mm connector (see picture on the left). Longer
connectors could damage the device.

Puls

.

.

CLEANING

• Disconnect the device from the electrical power supply before cleaning or performing maintenance

operations.

• U

se only ge

ntl

e

cleaning agent

s a

nd

no abrasive cl

eaning t

ool

s

.

WARNING:
Disconnect the power supply before proceeding with installation.
The installation has to be performed only by authorized personnel.

Thread

Fastening
area

Insulation

Connector 2 Faston 6,3x0,8mm.

Backlit "On/Stand-by" button

Temperature Sensor

Power supply cable

“Boost” and “Timer” LED

Button for “Boost 2h” and
“Timer” modes

Temperature setting knob
(Range 7

°

C – 32

°

C)

Wrench

Back fastening screw

Heating element connector

Earth connection (only Class I)

Ring

“O-Ring”

Heating Element

“Thesis Easy”

Electronic Control for Towel Heaters

Comfort technology division

Selmo

Selmo

Electronic

Via Pacinotti, 24 - 35030 Rubano

www.selmo.it

(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo

Electronic

Via Pacinotti, 24 - 35030 Rubano

www.selmo.it

EN

Rev. 01 -  Oct. 2018

Summary of Contents for Thesis Easy

Page 1: ...usted in order not to exceed 3 C At the end of the 2 7 hours period the device returns to previous operational mode Stand by mode THESIS EASY is a special device that controls the power output of the...

Page 2: ...2h Timer Connector of the heating element 6 3x0 8mm Faston Neutral Class I Phase Ground Temperature sensor 10KOhm a 25 C Type NTC Compliant standards EN55014 1 EN55014 2 EN61000 3 2 EN61000 3 3 EN6033...

Page 3: ...e of damage of the power supply cable shut down the device and do not tamper with it The damaged power supply cables can be replaced exclusively by the manufacturer or by an authorized service center...

Page 4: ...r supply before proceeding with installation The installation has to be performed only by authorized personnel Threa d Fastening area Insulation Connector 2 Faston 6 3x0 8mm Backlit On Stand by button...

Page 5: ...diator properly secure it and insert the cover ring 14 Extract the connecting cables from the device The two Faston connectors and the Class I ground connector 15 Insert the 2 Faston into the relevant...

Page 6: ...cting part to the heating element is kept hidden by this special layout so that the device ts perfectly to the towel radiator Blue red backlit button The backlight indicates the status of the system T...

Page 7: ...fter that 7 i O t returns into mode and after 22 hours the Boost mode is started again for 2 hours This sequence will repeat endlessly Timer 24h mode T24h command starts 2h Boost automatically every d...

Page 8: ...d Boost mode active The heating element remains active for 2h For safety reasons the maximum temperature is of 3 C 7 Control Led Blinking green Boost mode active Timer 24 The heating element remains a...

Reviews: