Water protection:

The IP44 protection level is
guaranteed by a special
design of the connection
parts.

Cable locking system:

According to the IEC
directives and fulfilling the
IP44 requirements, this
mechanism extends life of
the power cable.

Small dimensions:

Reduced device volume and thickness.

Internal buzzer:

For acoustic
warnings
according to
EN60335-1
directive.

External sensor:

Guarantees a stable room temperature and a prompt reaction in case of strong temperature
variation.

Plastic cover:

The

connecting part to the
heating element is kept
hidden by this special
layout, so that the device
fits perfectly to the towel
radiator.

Blue / red backlit button:

The

backlight indicates the status of
the system.

Thermostat knob with button:

For easily setting the desired
“Comfort”

and for

power

activating the “Boost” and “Timer”
modes.

Red / green / amber Boost Led:

A small light indication informs the user
when “Boost” and “Timer” modes are
active.

Quick Guide

Off

Off

Off

“Thesis Easy”

Electronic Control for Towel Heaters

Comfort technology division

Selmo

Selmo

Electronic

Via Pacinotti, 24 - 35030 Rubano

www.selmo.it

(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo

Electronic

Via Pacinotti, 24 - 35030 Rubano

www.selmo.it

EN

Rev. 01 -  Oct. 2018

Summary of Contents for Thesis Easy

Page 1: ...usted in order not to exceed 3 C At the end of the 2 7 hours period the device returns to previous operational mode Stand by mode THESIS EASY is a special device that controls the power output of the...

Page 2: ...2h Timer Connector of the heating element 6 3x0 8mm Faston Neutral Class I Phase Ground Temperature sensor 10KOhm a 25 C Type NTC Compliant standards EN55014 1 EN55014 2 EN61000 3 2 EN61000 3 3 EN6033...

Page 3: ...e of damage of the power supply cable shut down the device and do not tamper with it The damaged power supply cables can be replaced exclusively by the manufacturer or by an authorized service center...

Page 4: ...r supply before proceeding with installation The installation has to be performed only by authorized personnel Threa d Fastening area Insulation Connector 2 Faston 6 3x0 8mm Backlit On Stand by button...

Page 5: ...diator properly secure it and insert the cover ring 14 Extract the connecting cables from the device The two Faston connectors and the Class I ground connector 15 Insert the 2 Faston into the relevant...

Page 6: ...cting part to the heating element is kept hidden by this special layout so that the device ts perfectly to the towel radiator Blue red backlit button The backlight indicates the status of the system T...

Page 7: ...fter that 7 i O t returns into mode and after 22 hours the Boost mode is started again for 2 hours This sequence will repeat endlessly Timer 24h mode T24h command starts 2h Boost automatically every d...

Page 8: ...d Boost mode active The heating element remains active for 2h For safety reasons the maximum temperature is of 3 C 7 Control Led Blinking green Boost mode active Timer 24 The heating element remains a...

Reviews: