4.2
/ Maintenance and trouble shooting
The operations that can be done by user are limited to installation and connecting up.
Any dismantling, repair or modification to the overfill prevention device automatically cancels the
manufacturer’s
warranty.
Consequently, this work can only be done by the «Self Climat» company after return of the appliance to
the
factory.
In the event of a fault on the overfill prevention device it should be returned to:
Self Climat
Z.I. Sud - Rue des Epinettes
CS 50152 TORCY
77208 MARNE LA VALLÉE CEDEX 1
FRANCE
Any maintenance must be carried out according to EN standards in force in the country in use covering
means
of exploitation in potentially explosive zone. The national regulations must be followed. Any
operation must
be carried out by qualified staff.
4.3
/ Dismantling
The overfill prevention device can only be dismantled in the event of malfunctioning or replacement.
It can only be dismantled by personnel authorized to work on equipment for use in explosive atmospheres.
Self Climat automatic overfill prevention devices are guaranteed for one year from the invoice date against
manufacturing faults accepted by our factory.
Our overfill prevention devices cannot be modified in any way without causing a loss warranty.
As we do not install the equipment ourselves no claim whatsoever for indemnity will be accepted whether
for
direct or indirect causes.
Perspective 1
1) Tester Ref : 308 267
Composition
-
Stainless steel cable Ø 1 mm Lg 2 m at one
end a traction ring and at the other a cable
clamp.
-
Brass union Ø 1’’ F, fitted with a cover on a
chain.
Tester in the rest position – fitted on the OPD Standard
V) SPECIAL CONDITIONS
VI) OPTIONAL ACCESSORIES
1’’ tapping
+/- 180 mm
Self Climat OPD
DN 80
17/40