background image

 

INTRODUCTION 

Thank you for your purchase of the Selectronic Sine wave inverter, model WM1400-12V. 
Your WM1400 is a state-of-the-art high performance TRUE SINE WAVE DC-AC Inverter. 

Many hours of development time have been invested in the WM1400 so that we can provide you with 
a reliable high quality inverter. The output from your WM1400 is as good as, if not better than mains 
power. If looked after properly, the WM1400 will give you many years of reliable service. 

WARRANTY CARD 

Before proceeding any further, it is extremely important that you complete your warranty card 
NOW. This will enable us to immediately register your 5 year warranty period. By accurately 
completing your warranty card, you will provide us with valuable information that will assist us in 
keeping up with your alternative energy needs. Please take a few moments to fill in the warranty 
card. Your efforts will be greatly appreciated. 

INSTALLATION 

The installation of your inverter is extremely important. Failure to follow  the recommended 
installation instructions may void your warranty. If in doubt, ask your supplier. 

After unpacking, check for any damage that may have occurred during transit. If there are any signs of 
damage, contact your supplier immediately. 

The Inverter must be installed in a dry, cool, dust-free environment. 

Please leave at least 300mm clearance around the sides and top of the Inverter and approximately 
200mm at the base as this will aid the natural cooling of the Inverter. The air vents on the underside of 
the WM1400 also need to be kept clear of obstructions. 

BASE

300mm

300mm

Mode

PROUDLY DESIGNED & MADE IN AUSTRALIA

Demand Start Adjust

Low Volts Adjust

Alarms

DC POWER

4 Watts

DC Volts Low/High

TEMP Overload

8 Watts

DC    TO    AC      POWER

STATUS

AC Volts ON

AC Overload

12 Watts

16 Watts

Off

O N

DEMAND START

30mm

160mm

385mm

 

We suggest that you house your Inverter and other power generating equipment in a purpose built shed 
sited remotely from the home, and as far away as possible from any radio transmitters or receivers. 
Also make sure that the exhaust from your generator or other sources of heat or fumes are kept well 
away from the WM1400. SEIA (Sustainable Energy Industry Association (Australia) Ltd) installation 
guidelines must be followed. 
You must have a suitable 12V DC battery bank that is maintained and operated to the battery 
manufacturer’s recommendation. To ensure operation to WM1400 specification, the battery bank 
should have a minimum capacity of 500 ampere hours at the 100 hour discharge rate 12V systems (ask 
your supplier if in doubt). Smaller capacity batteries can be used but may result in  degraded 
performance of the WM1400 under heavy surge conditions. 

Summary of Contents for WM1400-12V

Page 1: ...1400 12V OWNERS MANUAL Serial No _____________________________ Purchase Date ______________ Note Your Warranty can only be valid once your warranty card is completed and returned to Selectronic Australia ...

Page 2: ......

Page 3: ...TENANCE 11 WM1400 MAINTENANCE 11 BATTERY MAINTENANCE 11 RADIO FREQUENCY INTERFERENCE 12 USING A SELECTRONIC KEYPAD WITH THE WM1400 12 13 SERIAL PORT WIRING 13 KEYPAD WIRING 13 KEYPAD FRONT PANEL Display not shown for clarity 13 STATUS 14 READINGS Keypad Grey Keys 14 SETTINGS Keypad Light Blue Keys 15 OPTIONS Keypad Light Blue Keys 16 DIAGNOSTICS Keypad Light Blue Keys 16 INVERTER ALARMS 16 WM1400 ...

Page 4: ...he Inverter must be installed in a dry cool dust free environment Please leave at least 300mm clearance around the sides and top of the Inverter and approximately 200mm at the base as this will aid the natural cooling of the Inverter The air vents on the underside of the WM1400 also need to be kept clear of obstructions BASE 300mm 300mm Mode PROUDLY DESIGNED MADE IN AUSTRALIA Demand Start Adjust L...

Page 5: ...inverter should be used If in any doubt see your supplier or installer BATTERIES High quality deep cycle batteries offer good performance and are available in a wide variety of sizes DO NOT USE ordinary car batteries or engine starting batteries If a battery is rated only in Cold Cranking Amps CCA and reserve capacity it is designed to start an engine Most hybrid type wet cell batteries will have ...

Page 6: ...aker on the front panel is in the OFF position LEVER DOWN Now connect the battery cables RED BATTERY POSITIVE BLACK BATTERY NEGATIVE These connections should be tight If using nuts bolts and washers they should be stainless steel At this point re check the connections before proceeding any further WARNING IF THE WM1400 EMITS A VERY LOUD TONE THE BATTERY LEADS HAVE BEEN CONNECTED IN REVERSE POLARIT...

Page 7: ...e too small to be sensed in the STANDBY mode The only disadvantage is that when the appliances are off the WM1400 will be drawing more power than it would in STANDBY mode When you first apply power the WM1400 will be in STANDBY mode There will be a quiet pulsing sound The WM1400 is now ready for use Mode Demand Start Adjust Low Volts Adjust Alarms 4 Watts DC Volts Low High TEMP Overload 8 Watts ST...

Page 8: ...uts down because the battery volts are too high then this LED will come ON It will remain ON until normal battery volts are restored If the inverter shuts down due to not enough battery volts then LED 3 will flash LED 3 will continue to flash until the battery volts have risen sufficiently In this case charge the battery by starting the vehicle or using a battery charger The low voltage point that...

Page 9: ... button until the desired value is sought LED s 1 4 will return to Status Indication after 10 seconds if a key is not pressed Low Volts Cut out LED 1 LED 2 LED 3 LED 4 10 0 Volts ON 10 1 Volts Slow flash ON 10 2 Volts Medium flash ON 10 3 Volts Fast flash ON 10 4 Volts Fastest flash ON 10 5 Volts ON 10 6 Volts Slow flash ON 10 7 Volts Medium flash ON 10 8 Volts Fast flash ON 10 9 Volts Fastest fla...

Page 10: ...s could be potentially dangerous so we advise you to consult your system designer immediately 4 INVERTER SHUTS DOWN WITH LOW VOLTS If your WM1400 has shut down because of low DC volts it could be due to the following 1 A sustained large load could be causing the battery volts to drop below the cut out voltage a The Battery Bank is too small for the loads you wish to use consult your system designe...

Page 11: ...es of such high capacity it is essential that you wear protective clothing some form of eye protection and rubber soled work boots Please regard your batteries with a great deal of caution and if in any doubt entrust this work to your installer 1 Every week carry out a thorough visual inspection of all battery wiring taking particular note of the condition of inter connections between cells 2 Chec...

Page 12: ...I in your installation It is recommended that the power system including the inverter be housed at least 15 metres from the home Ensure an earth stake is placed as close to the inverter as possible and connected to the inverter via a short length of wire See the INSTALLATION section of this manual for wiring Avoid running DC cables into the home if at all possible If this cannot be avoided run DC ...

Page 13: ...Receive 7 White with brown stripe 8 Brown KEYPAD WIRING Serial Port looking at the base of the inverter 1 2 3 4 5 6 7 8 Keypad from rear 1 2 3 4 5 6 KEYPAD FRONT PANEL Display not shown for clarity NEXT DISPLAY UP DOWN SETTINGS OPTIONS DIAG NOSTICS CURRENT SHUNT 1 CURRENT SHUNT 2 CURRENT SHUNT 3 AC LOAD READINGS INPUT READINGS GENERATOR CONTROL INVERTER STATUS TIME BATTERY READINGS ALARM Remote Ke...

Page 14: ...t conserves valuable battery power when no appliances are on The amount of power or load that the Inverter needs to start up is adjustable see page 5 for details CONT mode CONTINUOUS means that the Inverter will be on at all times regardless of whether appliances are connected or not This situation is useful if you have small loads such as a VCR or digital clock that requires 24 hour power or if l...

Page 15: ...oggle between ON or OFF state This is set to ON at the factory Buzzer ON Set Parameters Indicates the end of the set parameters menu Press any grey keypad key to return you to the STATUS menu and save your settings Demand Start When in STANDBY mode the inverter will require a load of 4 watts or greater to turn on to full 240V power This setting can be adjusted between 4 to 16 watts In most cases t...

Page 16: ...ash and the buzzer will sound on an Inverter Alarm END Alarms Press the NEXT key to access diagnostics screens Press NEXT key Diagnostics Indicates transformer temperature Note the reading is NOT in degrees Celsius Tx Temp 1 Diagnostics Indicates Heatsink temperature Note the reading IS in degrees Celsius HS Temp 53C Diagnostics Indicates Demand Start current level D S I 2 Diagnostics Indicates th...

Page 17: ... Factory Setting Output Voltage 240V AC 4 Nominal DC Input No Load to Full Load Output Current 5 8A AC 15A AC Max Continuous Max Surge Output Wave Shape Output Frequency Total Harmonic Distortion Efficiency True Sine Wave 50Hz 0 01 4 Peak 91 Full load 85 Power Factor Limitations Nil Input Output Isolation 1 875VAC Memory Retention Permanent Operating Temperature Range 10 C to 50 C Conforms to stan...

Page 18: ...AL AS LANDLINE POWER It is necessary for your safety to ensure that all Remote Area power system installations meet and comply with the relevant provisions and requirements of AS3000 wiring standards and AC wiring is installed by a Registered Electrical Contractor ...

Page 19: ...ncurred Unless otherwise specified to the purchaser the benefits conferred by this voluntary warranty are additional to all other conditions warranties guarantees rights and remedies expressed or implied by the Trade Practices Act in your state or territory All installation and user conditions as set down in the instruction manual must be strictly adhered to failure to do so may void your warranty...

Page 20: ...tral Nimbin NSW 2171 NSW 2480 Australia Australia Ph 02 9606 0279 Ph 02 6689 1430 Fax 02 6689 1109 Reid Technology Ltd 3 5 Auburn Street Solar Inverter Services Takapuna 13 Thirteenth Ave North Shore City Sawtell Auckland NZ NSW Ph 9 489 8100 2452 Fax 9 489 8585 Ph 02 66581733 ps reidtechnology co nz Suite 5 20 Fletcher Road Mooroolbark Victoria 3138 Australia Phone 61 3 9727 6600 Fax 61 3 9727 66...

Reviews: