Selecon 5.5-13 Operation Manual Download Page 5

Pacific Operation Manual 

 

 

 

 

 

 

 

Version 4 October 2010 

 

 

For ease of shipping, the Pacific VNZ is supplied 
with the lamp house removed. Attach the lamp 
house by sliding it into the guides on the rear of 
the lens tube, and then fastening the lamp house 
locking clamp. Attach the supplied safety chain 
between the luminaire anchor point, and the rear 
anchor point of the lens tube (see below). 
 

 

To  enable  the  balancing  of  the  Pacific  VNZ,  the 
yoke is mounted on the lens tube. The balancing of the Pacific VNZ is best done when the luminaire is  being 
unpacked for use. Please refer to page 7 for more details. The lamp house has no yoke fitted. A yoke can be 
fitted if the lamp house is to be used with other lens barrels. Please contact your Philips Selecon distributor for 
order codes. 
 
Familiarise yourself with the way the shutter assembly can be rotated by loosening the shutter assembly knob 
on the rear of the tube, and turning the assembly. Note how the colour frames are locked into the front of the 
lens tube with the colour frame locking clip and plunger. 
 
The  Pacific  VNZ  provides  for  mounting  2  gobo  holders.  Practice  inserting  them  into  both  the  front  and  rear 
position as it is easier to familiarise yourself with something new while it is on the ground rather than up in the 
air.  
 

Lamp Replacement & adjustment: 

 

Isolate electrically before re-lamping the luminaire. Also be aware that the lamp or luminaire may still 
be hot, so exercise necessary caution to avoid burns. 

 
To ensure optimum performance from your Pacific luminaire, follow the steps below: 

Centering the lamp 

Remove the lamp holder module as described above.  

Set the level of the metal cup holding the lamp base. The metal cup has a line around it. This level is 
factory set to the optimum position, and the luminaire output is then confirmed with test equipment. 
The optimum position has the line level with the edge of the module. 

 

First level the cup with the edge of the module by adjusting the three levelling screws. Then set to the 
correct height as detailed above. 

Remove the old lamp.  Align the pins of the new lamp to the correct holes and push the lamp firmly 
home.  Do not touch the quartz envelope of the lamp with your fingers - use the plastic or paper 
sheath supplied to insert the lamp. 

Carefully replace the lamp holder module and tighten the thumbscrew to lock it into position. 
Reconnect the luminaire to the power supply. 

Turn on the luminaire to approximately 30%. This makes the peak easier to see, and reduces the 
stress on the filament. Set the beam angle to its widest with a sharp edge. 

Centre the lamp in the middle of the beam if necessary, by adjusting the three levelling screws. 

 

Summary of Contents for 5.5-13

Page 1: ...E TO PROVIDE YOU WITH A SUPERIOR FITTING IN PERFORMANCE DESIGN ENGINEERING WE ARE CONFIDENT THAT IT WILL PERFORM TO YOUR EXPECTATIONS FOR MANY YEARS TO COME Caution Installation is entirely at your ri...

Page 2: ...sulting from the customer s failure to follow the installation operating maintenance and safety procedures in this manual or those generally applicable to lighting equipment The foregoing limitation e...

Page 3: ...further assistance contact your local Philips Selecon dealer or Philips Selecon 2 Safety Warnings 4 Operating your luminaire for the first time 4 Centering the lamp 5 Centre the lamp in the middle of...

Page 4: ...minaires are not suitable for mounting on a normally flammable surface These luminaires are not suitable for outdoor use They are rated at IP00 The luminaire should be at least 1 0 metre away from the...

Page 5: ...t is on the ground rather than up in the air Lamp Replacement adjustment Isolate electrically before re lamping the luminaire Also be aware that the lamp or luminaire may still be hot so exercise nece...

Page 6: ...gear anti clockwise until the distribution appears even across the beam Lamps The Pacific range is available with 5 different lamp holder modules The lamp holder module with a RED handle has a GY9 5 t...

Page 7: ...es either side of horizontal To mount on a theatre standard scaffold pipe 48mm O D Use a theatre hook clamp Order Code 20HC Your luminaire is supplied with an M12 or for the US set screw two washers a...

Page 8: ...ains etc Note that on the Pacific range of luminaires the shutters are not removable The shutter assembly can be rotated by loosening the shutter assembly knob on the back of the lens tube and twistin...

Page 9: ...itted when the accessory is no longer used To fit an accessory in the rear mounting slot Remove the accessory slot cover using a Philips screwdriver Slide the pattern holder against the rear shutter p...

Page 10: ...losed and lens access knob is securely screwed home All safety anchor bonds are fitted Any accessories are correctly installed and secured Colour frame retention clip is locked down Lamp Module is sec...

Page 11: ...ips Selecon Return Authorisation Form available from Philips Selecon Return the luminaire to Philips Selecon or its authorised agent If Philips Selecon accepts the warranty claim Philips Selecon will...

Page 12: ...19PACLM6 Lamp holder module 1000W 19PACLM1 Lamp holder module 575W MSR 19PACLMMSRI Lamp holder module 575W MSR Hot Restrike 19PACLMHRMSR Lamp holder module 80V 1200W inc power supply 18PAC80VASS2 Elec...