Selecon 5.5-13 Operation Manual Download Page 3

Pacific Operation Manual 

 

 

 

 

 

 

 

Version 4 October 2010 

 

 

 

      

         

       

       

 

 

     Lamp module GKV 600/800W        Lamp Module 80V 1200W  

  Lamp Module BP1000W            Lamp Module CDM 150                                                          

…………..

Blue Handle                    

 

 

            Red Handle                              Black Handle 

 

Please read this information carefully to ensure that you are fully conversant with its 
operation. 

 
Subject to the right to use its luminaires, Philips Selecon does not convey any right, title or interest in its 
intellectual property, including, without limitation, its patents, copyrights and know-how. If you would like 
further assistance contact your local Philips Selecon dealer or Philips Selecon. ................................................ 2

 

Safety Warnings ................................................................................................................................................... 4

 

Operating your luminaire for the first time ............................................................................................................ 4

 

Centering the lamp ............................................................................................................................................... 5

 

Centre the lamp in the middle of the beam if necessary, by adjusting the three levelling screws. Optimising the 
output .................................................................................................................................................................... 6

 

Lamps ................................................................................................................................................................... 6

 

Mounting your luminaire ....................................................................................................................................... 7

 

To mount on a theatre standard scaffold pipe ...................................................................................................... 7

 

To mount on a telescopic stand ............................................................................................................................ 7

 

Adjustable Yoke .................................................................................................................................................... 7

 

Operating your luminaire ...................................................................................................................................... 8

 

Pan and Tilt Adjustment........................................................................................................................................ 8

 

Focusing Pacific Zoomspot models ...................................................................................................................... 8

 

Shutter System ..................................................................................................................................................... 8

 

Accessory mounting positions .............................................................................................................................. 8

 

Colour Filter Life ................................................................................................................................................... 9

 

Safe Practice ......................................................................................................................................................10

 

Rigging Check-list ...............................................................................................................................................10

 

Maintenance .......................................................................................................................................................10

 

Safety ..................................................................................................................................................................11

 

LIMITED WARRANTY ........................................................................................................................................11

 

Accessories and codes .......................................................................................................................................12

 

 

Summary of Contents for 5.5-13

Page 1: ...E TO PROVIDE YOU WITH A SUPERIOR FITTING IN PERFORMANCE DESIGN ENGINEERING WE ARE CONFIDENT THAT IT WILL PERFORM TO YOUR EXPECTATIONS FOR MANY YEARS TO COME Caution Installation is entirely at your ri...

Page 2: ...sulting from the customer s failure to follow the installation operating maintenance and safety procedures in this manual or those generally applicable to lighting equipment The foregoing limitation e...

Page 3: ...further assistance contact your local Philips Selecon dealer or Philips Selecon 2 Safety Warnings 4 Operating your luminaire for the first time 4 Centering the lamp 5 Centre the lamp in the middle of...

Page 4: ...minaires are not suitable for mounting on a normally flammable surface These luminaires are not suitable for outdoor use They are rated at IP00 The luminaire should be at least 1 0 metre away from the...

Page 5: ...t is on the ground rather than up in the air Lamp Replacement adjustment Isolate electrically before re lamping the luminaire Also be aware that the lamp or luminaire may still be hot so exercise nece...

Page 6: ...gear anti clockwise until the distribution appears even across the beam Lamps The Pacific range is available with 5 different lamp holder modules The lamp holder module with a RED handle has a GY9 5 t...

Page 7: ...es either side of horizontal To mount on a theatre standard scaffold pipe 48mm O D Use a theatre hook clamp Order Code 20HC Your luminaire is supplied with an M12 or for the US set screw two washers a...

Page 8: ...ains etc Note that on the Pacific range of luminaires the shutters are not removable The shutter assembly can be rotated by loosening the shutter assembly knob on the back of the lens tube and twistin...

Page 9: ...itted when the accessory is no longer used To fit an accessory in the rear mounting slot Remove the accessory slot cover using a Philips screwdriver Slide the pattern holder against the rear shutter p...

Page 10: ...losed and lens access knob is securely screwed home All safety anchor bonds are fitted Any accessories are correctly installed and secured Colour frame retention clip is locked down Lamp Module is sec...

Page 11: ...ips Selecon Return Authorisation Form available from Philips Selecon Return the luminaire to Philips Selecon or its authorised agent If Philips Selecon accepts the warranty claim Philips Selecon will...

Page 12: ...19PACLM6 Lamp holder module 1000W 19PACLM1 Lamp holder module 575W MSR 19PACLMMSRI Lamp holder module 575W MSR Hot Restrike 19PACLMHRMSR Lamp holder module 80V 1200W inc power supply 18PAC80VASS2 Elec...