19
2 mm
WL
15. Loosen the screws of the torque tube somewhat and feed the torque tube on to the luff section. Protect
the luff section and the torque tube with paper or plastic. Secure the torque tube with tape before rigging.
Mark the luff section 67 mm from the edge of the luff section to help aligning the screws with the holes
in the luff section at a later stage. Use a permanent marker pen.
4.2
Note! For systems with swaged stud terminal, skip this part and go directly to 4.3.
1. Before cutting the wire, measure the wire from the centre of the hole in the top swaged eye terminal.
Mark the measurement WL carefully on the wire using a marker pen. (The WL measurement was calculated
in ”Table 2”, (Chapter 2.5).
2. Put adhesive tape around the wire on both sides of the cutting mark to assist cutting. Carefully cut the
wire using a hacksaw.
3 . Unscrew the socket, wedge and former from the terminal part (or Furlex rigging screw).
Note! Remove locking tube from rigging screw and slide it over the lower luff extrusion. Secure it
temporaily with a piece of tape.
4.
Thread the socket onto the wire.
5. Slide the wedge over the core (7 strands) of the wire . The core of the wire should protrude approx.
2 mm from the wedge.
15.
4.2 Fitting the Sta-lok eye terminal (with or without rigging screw).
Former
Terminal part (or rigging screw)
Wedge
Socket
Fig. 4.2.a
Fig. 4.2.b
Fig. 4.2.c
Fig. 4.2.d
Fig. 4.1.j
67