![Selbit ISP-12F Manual Handbook Download Page 9](http://html1.mh-extra.com/html/selbit/isp-12f/isp-12f_manual-handbook_1236443009.webp)
www.selbit.pl
- 9 -
Connector of the adjuster Connections of the frequency converter
ISP-12F (PWR CONVERTER ATV 320 3*380V)
+24 ------------------------------------------------------ +24
GND (-24V) ------------------------------------------- COM
L6 ------------------------------------------------------- DI6
L5 ------------------------------------------------------- DI5
L4 ------------------------------------------------------- DI4
L3 ------------------------------------------------------- DI3
L2 ------------------------------------------------------- DI2
L1 ------------------------------------------------------- DI1
The screen (braid) - COM connect only from the side of the inverter!
Figure 7
Connection of electrical terminals of the ATV 320 converter
Prepared cables connections and casing assembly of the controller.
Please connect power cable TS 8/24 (SEC,12 V), (with prepared cables’ tips) to the junction
marked as PWR on the controller’s main plate.
Rotating encoder’s connection:
Encoder cables please connect with junctions marked ENCODER as follow:
-
brown cable with (+24) plus controller’s connection
-
blue cable with (GND) minus controller’s connection
-
white cable with (IN-1) connection
-
black cable with (IN-2) connection.