www.selbit.pl
- 15 -
(K-2) Setting of electrical parameters of the drive (continued)
Input by: ConF – FULL – drC -
Function
Value
Description of the function
Ctt
UUC
Voltage vector control
(K-3) Configuration of control inputs
Input by: ConF – FULL – I-O -
Function
Value
Description of the function
tCC
2C
2-wire control
tCt
trn
Status change is required to trigger the input
Frd
LII
Terminal DI1 triggers downward motion (forward)
rrS
LI2
Terminal Di2 triggers upward movement (backward)
(K-4) Configuration of control inputs (continued)
Input by: ConF – FULL – Fun – PSS -
Function
Value
Description of the function
PS2
LI3
Terminal DI3 triggers the set speed
PS4
LI4
Terminal DI4 triggers the set speed
SP2
10
Second set speed (not used)
SP3
10
Frequency of free movement to position (Hz)
SP4
= > from the value
set in the function tFr
Frequency of fast motion (Hz)
(K-5) Configuration of control inputs (continued)
Input by: ConF – FULL – Fun – LPO-
Function
Value
Description of the function
SAF
LI6
Terminal DI6 – limit switch down
SAr
LI5
Terminal DI5 – limit switch up
SAL
LO
Triggering with a low logic state from limit switches
PAS
rnP
Type of stop after a signal from limit switches (ramp)
dSF
Std
Type of stop (standard)
nSTP
nO
Limit switch operation memory (off)
Summary of Contents for ISP-12F
Page 12: ...www selbit pl 12 Figure 11 Block diagram for rotary encoder...
Page 27: ...www selbit pl 27...
Page 29: ...www selbit pl 29...