Table 4

Factory Default Front-Panel Interface Definitions (see Figure 14)

Function

Definition

PUSHBUTTONS

Except for 

TARGET RESET

/

LAMP TEST

, the pushbuttons have dual functions (primary/secondary). 

After you select a primary function (i.e., 

METER

 pushbutton), the pushbuttons operate on their 

secondary functions (

CANCEL

SELECT

, left/right arrows, up/down arrows, 

EXIT

) so you can scroll 

through information, activate settings/control, etc., on the LCD.

CONTROL ENABLED

a

a

These indicated LEDs and the operator control have fixed functions. Programming at a higher logic level can change functions of all other LEDs 
and operator controls (with corresponding status LEDs).

SEL-351R Falcon Recloser Control is enabled.

AC SUPPLY

Adequate Vac power is present.

BATTERY PROBLEM

Indicates battery problems.

HOT LINE TAG

No closing or autoreclosing can take place via the control.

TRIP

Trip occurred.

FAST CURVE

Fast curve overcurrent element trip.

HIGH CURRENT

High-set overcurrent element trip.

81

Underfrequency trip.

RESET

The control is in the reset state, ready for a reclose cycle.

CYCLE

The control is actively in the trip/reclose cycle mode.

LOCKOUT

All reclose attempts were unsuccessful.

A

B

C

a

A-, B-, or C-phase involved in fault.

G

Ground involved in fault.

SEF

Sensitive earth fault overcurrent element trip.

GROUND ENABLED

Enables/disables ground overcurrent elements.

RECLOSE ENABLED

Enables/disables autoreclosing.

REMOTE ENABLED

Enables/disables remote control.

ALTERNATE SETTINGS

Switches active setting group between main and alternate setting groups.

LOCK

 (press for 3 seconds)

Blocks the function of other operator controls (except 

WAKE UP

 and 

TRIP

). Three-second delay to 

engage/disengage.

AUX 1

User programmable; e.g., program to Trip Test—test autoreclose logic without applying current.

AUX 2

User programmable; e.g., program to enable/disable fast-curve tripping.

WAKE UP

a

Wakes up the control after it has been put to sleep.

CLOSE

/

RECLOSER CLOSED

Close recloser/recloser closed status.

b

b

You can set the 

CLOSE

 operator control with a delay, which allows an operator to press 

CLOSE

 and then move a safe distance away from the recloser 

before closing proceeds.

TRIP

/

RECLOSER OPEN

Trip recloser (go to lockout)/recloser open status.

c

c

You can set the 

TRIP

 operator control with a delay, which allows an operator to press 

TRIP

 and then move a safe distance away from the recloser 

before tripping proceeds.

Summary of Contents for SEL-351R Falcon

Page 1: ...BITS communi cations speeds protection and improves security Customize controls by using enhanced SELOGIC control equations for improved system operation Configurable front panel control labels simpl...

Page 2: ...ose interval The reset times are set separately for reset timing for an auto reclose and reset timing for a manual remote close from lockout Traditionally the reset time for a manual remote close from...

Page 3: ...y inverse class C extremely inverse long time inverse short time inverse Programmable curves user designed Four 4 programmable curves Optional 3 Phase Voltage connect to voltage channels V1 V2 and V3...

Page 4: ...er wear monitor measures unfiltered ac current at the time of trip and the number of close to open operations as a means of monitoring this wear Every time the recloser trips the recloser control reco...

Page 5: ...27 IRIG B SERIAL PORT 1 1 2 3 4 5 N C 7 8 SERIAL PORT 2 SERIAL PORT 3 OUT102 OUT101 OUT104 OUT103 OUT107 N C N C IN101 ALARM IN103 IN102 N C N C IN104 _ RECLOSER CONTROL I1 Z01 I2 Z02 I3 Z03 IN Z04 12...

Page 6: ...ttings Create Application Designs that include the most commonly used relay features and settings for your system see Figure 6 and watch commissioning times drop drastically Figure 6 Example Applicati...

Page 7: ...ress for 3 sec AUX 1 AUX 2 WAKE UP CLOSED RECLOSER OPEN RECLOSER TRIP CLOSE C B A LOCKOUT CYCLE CURVE FAST TAG HOT LINE PROBLEM BATTERY SUPPLY AC CURRENT HIGH 81 G SEF RESET A01 A04 A03 A02 A07 A06 A0...

Page 8: ...CLE CURVE FAST TAG HOT LINE PROBLEM BATTERY SUPPLY AC CURRENT HIGH 81 G SEF RESET A01 A04 A03 A02 A07 A06 A05 A08 A11 A10 A09 A14 A13 A12 A23 A16 A15 A17 A18 A22 A20 A19 A21 A26 A25 A24 A28 A27 IRIG B...

Page 9: ...digital quantities having a logical value of either 0 or 1 The terms assert or asserted refer to a Relay Word bit that has a value of 1 or is changing from 0 to 1 The terms deassert or deasserted refe...

Page 10: ...ry monitor charger the SEL 351R Falcon can monitor battery voltage The SEL 351R Falcon puts itself to sleep if voltage falls to a user set threshold or if a user set timer times out after an extended...

Page 11: ...n change most functions by programming to meet system requirements see Table 4 Use the optional configurable labels to customize the targets and control pushbuttons to best meet operational needs r Se...

Page 12: ...le CYCLE The control is actively in the trip reclose cycle mode LOCKOUT All reclose attempts were unsuccessful A B C a A B or C phase involved in fault G Ground involved in fault SEF Sensitive earth f...

Page 13: ...ol via serial communications These values shall be available for use in control logic Secure Communications The recloser control shall include an optional accessory for converting an EIA 232 serial po...

Page 14: ...tored Close Circuit Points Monitored Trip Circuit Points B D C A E F IRIG B 1 2 3 4 5 N C 7 8 FRONT PANEL OPERATOR CONTROLS 28 Vdc 24 Vdc 24 Vdc or 36 Vdc 12 Vdc FRONT PANEL TARGET LEDS AC SUPPLY CONT...

Page 15: ...Schweitzer Engineering Laboratories Inc SEL 351R Falcon Data Sheet 15 Relay Mounting Figure 16 SEL 351R Falcon Lift To Open Enclosure Dimensions and Mounting...

Page 16: ...SEL 351R Falcon Data Sheet Schweitzer Engineering Laboratories Inc 16 Figure 17 SEL 351R Falcon Swing Open Enclosure Dimensions and Mounting...

Page 17: ...ages Frequency and Rotation System Frequency 50 or 60 Hz Phase Rotation ABC or ACB Frequency Tracking Range 40 1 65 Hz Note Voltage connected to V1 required for frequency tracking Communications Ports...

Page 18: ...ow pass analog filtering Net filtering analog plus digital rejects dc and all harmonics greater than the fundamental Protection and Control Processing Four times per power system cycle Battery Monitor...

Page 19: ...20 C and at nominal system frequency unless noted otherwise Voltages VA VB VC VS 3V0 V1 V2 0 2 67 300 0 V wye connected Currents IA IB IC 1 A nominal 3 mA 0 1 0 1 20 A Temperature Coefficient 0 0002...

Page 20: ...laws in its products including without lim itation software firmware and documentation The information in this document is provided for informational use only and is subject to change without notice...

Reviews: