Schweitzer Engineering Laboratories, Inc.

SEL-351R Falcon Data Sheet

SEL-351R Falcon™ Recloser Control

Take Control of Your Recloser

Major Features and Benefits

The SEL-351R Falcon Recloser Control provides microprocessor-based features in a slim-profile housing for
long, reliable service on your distribution system.

Modernize existing recloser installations to provide cost saving protection, automation, and
control features. Single-person-lift size and standard control cable interconnection simplifies
installation. Available in Lift-To-Open and Swing-Open enclosure options.

Use automatic network reconfiguration for improved reliability. Patented M

IRRORED

 B

ITS

®

 

communi-

cations speeds protection and improves security.

Customize controls by using enhanced SEL

OGIC

®

 

control equations for improved system operation.

Configurable front-panel control labels simplify custom functions.

Improve feeder loading by using built-in, high-accuracy metering functions. Use watt and var measure-
ments to optimize feeder operation. Measure three-phase values with either three potential transform-
ers or use “phantom” values derived from a single-phase voltage.

Increase efficiency of service restoration with accurate fault location when connected with three-phase voltages.

Reduce engineering costs with 

AC

SEL

ERATOR

 QuickSet

®

 SEL-5030 Software for relay settings and logic pro-

gramming. The built-in HMI provides phasor diagrams that help support commissioning and troubleshooting.

Power with 120 Vac or 230 Vac (or 125 Vdc or 250 Vdc).

Summary of Contents for SEL-351R Falcon

Page 1: ...BITS communi cations speeds protection and improves security Customize controls by using enhanced SELOGIC control equations for improved system operation Configurable front panel control labels simpl...

Page 2: ...ose interval The reset times are set separately for reset timing for an auto reclose and reset timing for a manual remote close from lockout Traditionally the reset time for a manual remote close from...

Page 3: ...y inverse class C extremely inverse long time inverse short time inverse Programmable curves user designed Four 4 programmable curves Optional 3 Phase Voltage connect to voltage channels V1 V2 and V3...

Page 4: ...er wear monitor measures unfiltered ac current at the time of trip and the number of close to open operations as a means of monitoring this wear Every time the recloser trips the recloser control reco...

Page 5: ...27 IRIG B SERIAL PORT 1 1 2 3 4 5 N C 7 8 SERIAL PORT 2 SERIAL PORT 3 OUT102 OUT101 OUT104 OUT103 OUT107 N C N C IN101 ALARM IN103 IN102 N C N C IN104 _ RECLOSER CONTROL I1 Z01 I2 Z02 I3 Z03 IN Z04 12...

Page 6: ...ttings Create Application Designs that include the most commonly used relay features and settings for your system see Figure 6 and watch commissioning times drop drastically Figure 6 Example Applicati...

Page 7: ...ress for 3 sec AUX 1 AUX 2 WAKE UP CLOSED RECLOSER OPEN RECLOSER TRIP CLOSE C B A LOCKOUT CYCLE CURVE FAST TAG HOT LINE PROBLEM BATTERY SUPPLY AC CURRENT HIGH 81 G SEF RESET A01 A04 A03 A02 A07 A06 A0...

Page 8: ...CLE CURVE FAST TAG HOT LINE PROBLEM BATTERY SUPPLY AC CURRENT HIGH 81 G SEF RESET A01 A04 A03 A02 A07 A06 A05 A08 A11 A10 A09 A14 A13 A12 A23 A16 A15 A17 A18 A22 A20 A19 A21 A26 A25 A24 A28 A27 IRIG B...

Page 9: ...digital quantities having a logical value of either 0 or 1 The terms assert or asserted refer to a Relay Word bit that has a value of 1 or is changing from 0 to 1 The terms deassert or deasserted refe...

Page 10: ...ry monitor charger the SEL 351R Falcon can monitor battery voltage The SEL 351R Falcon puts itself to sleep if voltage falls to a user set threshold or if a user set timer times out after an extended...

Page 11: ...n change most functions by programming to meet system requirements see Table 4 Use the optional configurable labels to customize the targets and control pushbuttons to best meet operational needs r Se...

Page 12: ...le CYCLE The control is actively in the trip reclose cycle mode LOCKOUT All reclose attempts were unsuccessful A B C a A B or C phase involved in fault G Ground involved in fault SEF Sensitive earth f...

Page 13: ...ol via serial communications These values shall be available for use in control logic Secure Communications The recloser control shall include an optional accessory for converting an EIA 232 serial po...

Page 14: ...tored Close Circuit Points Monitored Trip Circuit Points B D C A E F IRIG B 1 2 3 4 5 N C 7 8 FRONT PANEL OPERATOR CONTROLS 28 Vdc 24 Vdc 24 Vdc or 36 Vdc 12 Vdc FRONT PANEL TARGET LEDS AC SUPPLY CONT...

Page 15: ...Schweitzer Engineering Laboratories Inc SEL 351R Falcon Data Sheet 15 Relay Mounting Figure 16 SEL 351R Falcon Lift To Open Enclosure Dimensions and Mounting...

Page 16: ...SEL 351R Falcon Data Sheet Schweitzer Engineering Laboratories Inc 16 Figure 17 SEL 351R Falcon Swing Open Enclosure Dimensions and Mounting...

Page 17: ...ages Frequency and Rotation System Frequency 50 or 60 Hz Phase Rotation ABC or ACB Frequency Tracking Range 40 1 65 Hz Note Voltage connected to V1 required for frequency tracking Communications Ports...

Page 18: ...ow pass analog filtering Net filtering analog plus digital rejects dc and all harmonics greater than the fundamental Protection and Control Processing Four times per power system cycle Battery Monitor...

Page 19: ...20 C and at nominal system frequency unless noted otherwise Voltages VA VB VC VS 3V0 V1 V2 0 2 67 300 0 V wye connected Currents IA IB IC 1 A nominal 3 mA 0 1 0 1 20 A Temperature Coefficient 0 0002...

Page 20: ...laws in its products including without lim itation software firmware and documentation The information in this document is provided for informational use only and is subject to change without notice...