0000137188 Rev. 1.0
11
H
2
O
2
measurement display
Settings
Progrma Menu
H
2
O
2
Use
Enter
to access the sub-menus:
Hose
Conc.
Pump
H
2
O
2
Tube 6x10
Use
Enter
to modify the dimensions of
the hose (3x7 or 6x10mm) and the
system automatically calculates the flow
rate with the other hose without changing
any parameters (the factory-set hose is
6x10).
H
2
O
2
Conc 1.0 cc/m3
Enter the concentration value of the product
to be dosed with the 3x7 hose. This value
ranges from 1 to 4cc/m3. With the 6x10
hose the range is 1 to 15cc/m3.
H
2
O
2
Pump 20 m3/h
Enter the value of the system recirculation
pump. It ranges from 2 to 100m³/h
Advanced Display
Settings
Progrma Menu
Avdvanced
Use
Enter
to access the sub-menus:
Temp.
Flow
Cal.
Password
Avdvanced
Temp. 25°C
Press
Enter
and the + and - keys to set the
compensation temperature from 1 to 100°C.
If a temperature probe is connected, the
menu item will not be displayed as the
system will compensate automatically with
the value read by the probe itself.
Avdvanced
Flow On
Press
Enter
and the + and - keys to set the
flow to OFF or ON. This item enables or
disables the
Flow
inlet (see. Paragraph
10.0).
Avdvanced
Cal Full
Press
Enter
and the + and
– keys to set the
calibration to OFF or enable it to ON (Full)
Avdvanced
Password ****
Press
Enter
to set the system access and
modification password.
Use the + key to modify the figure and the
–
key to scroll to the next figure and confirm
with
Enter