0000137188 Rev. 1.0
10
8. PROGRAMMING
The programming menu can be accessed by simultaneously pressing the
Cal
and
Set
keys for at least 3 seconds.
Upon release of the keys the display will show:
To prime the
pH
pump, press the
UP
button for at least 3 seconds and release it to stop
the operation. To prime the
H
2
O
2
pump repeat the same procedure pressing the
DOWN
button for at least 3 seconds.
Progrma Menu
pH Measure
Use
Enter
to access the sub-menus:
Setpoint
Dos type
OFA time
Alr Band
Type
pH Measure
Setpoint 7.4 pH
Press
Enter
and the + and - keys to change
the Set Point value (0÷14 pH)
pH Measure
Sp Type Acid
Press
Enter
and the + and - keys to change
the Set Point type.
Acid
Alkaline
pH Measure
OFA Time Off
Press
Enter
and the + and - keys to set the
OFA time to OFF or from 1 to 240 min. (see
Paragraph 9.5)
pH Measure
Alr Band 3.0pH
Press
Enter
and the + and - keys to set the
band alarm from 1 to 3 pH.
pH Measure
Type PROP
Press
Enter
and the + and - keys to change
the dosing type.
PROP (see Paragraph 9.1).
ON/OFF (see Paragraph 9.2).
OFF (dosing disabled)
Language Display
Settings
Progrma Menu
Language EN
Press
Enter
and the + and
– keys to change
the language:
FR, EN, IT, ES, DE
pH measurement display
Settings