background image

Ni-Cd

Ni-MH

L照

6

Please note that the above addresses and phone numbers may be changed.

Installation of the product should be carried out by a qualified person.
Installation by an unqualified person is legally prohibited.

Don

t use the product in a strong corrosive gas atmosphere which contains hydrochloric acid or chlorine gases or the like.

Use in a corrosive gas atmosphere might cause the product to corrode and fall, resulting in an injury.

Do ’t use the produ t at a  oltage other tha  the rated  oltage i di ated o  the  a eplate.

Otherwise, breakage, fire or electric shock might result.

Before cleaning, be sure to turn off the power.
Otherwise, a fire or electric shock might result.

  CAUTION

Any product not marked as a product for outdoor use should not be used outdoors or in a humid place or near a water
source. Its use in such a place might cause a fire or electric shock.

The product should be mounted on a surface robust enough to support its weight, properly according to the instruction
manual. Improper installation might cause the product to fall or result in an electric shock or injury.

CONTACT DETAILS

Never touch LED light sources and their surroundings.
The light sources and their surroundings are very hot, so an accidental touch might cause a burn.

A lighting fitting has a service life. A product which has been used for eight to ten years may have degraded internal parts
even if it looks normal. For safety and energy saving, we recommend you check and replace it. The LED module design life is
6,0000 hours (different from the lighting fitting life) when used at an ambient temperature of 30°C, 10 hours per day, 3,000
hours per year. If used at a higher temperature or more hours per year, the life would be shortened. Have a specialist
inspect the product every three years. If used for an extended period without inspection, a smoke, fire, or electric shock
might result.

Fax

2-19-6 Yanagibashi, Taito-ku, Tokyo 111-0052 Japan

+81 3 5833 8971

+81 774 58 2034

+81 3 5833 8946  

Tokyo Branch

Fax

SEIWA ELECTRIC MFG.CO.,  LTD.

Phone

Phone

36 Shinike, Terada, Joyo, Kyoto Pref. 610-0192 Japan

Head Office

+81 774 55 8181

For further information on the product, contact any of our offices listed below (if you like to make an inquiry, let us know the model name
indicated on the product nameplate).

To ensure brightness and safety, carry out periodical cleaning and inspection.
If you find a problem, discontinue the use of the product and have it repaired by a specialist.

For a product marked with a frequency, don

t use the product at a frequency other than 50 or 60 Hz (local power supply

frequency). Use at a wrong frequency might cause a fire.

 JBRC

 

Japan Portable Rechargeable Battery Recycling Center

Phone +81 3 6403 5763

Resycling

Please bring used Secondary batteries to the recycling station for effective use of precious
resources and global environment conservation.

If you continue to use the product in an abnormal condition (smoke, odor, etc.), an explosion, a fire or electric shock might
result. If you detect an abnormality, immediately turn off the power switch. Confirm that the abnormal condition has been
eliminated and make a repair call.

   WARNING

- 2/2 -

Summary of Contents for LKBB

Page 1: ...the Installation Type column is a sign placed at the end of each model code to represent the type of installation Lamp house replacemen Special direct mount Direct mount Pipe pendant Bracket LKBB07051 LKBB07044 LKBB07052 Model 0 LKBB07045 LKBB07041 6 1 1H 2 2H 0 11E0200005A11 To be conserved Instruction Manual Prior to use Dust Ignition proof type LED Lighting Fittings LKBB07054 IP rating Type of ...

Page 2: ... box Confirm that the box does not turn The positioning box is not a supplied item Fit the short nipple and positioning box referring to the attached Short Nipple I stallatio Ma ual Fix the stand pole with the support not supplied and the positioning box mounting screws completely The pole has four 8 mm diameter holes arranged at pitches of 85x85 mm for the positioning box mounting screws After pu...

Page 3: ...the cable gland in the following order cover connecting member cable fixing member washer rubber sleeve washer body and lock nut The cable should be a round cable applicable to the rubber sleeve For information on cables applicable to the cable gland see the catalog If the lighting fitting is used in a place where water may splash on it waterproof the joint between the fitting and the existing sus...

Page 4: ...ive us any material showing the appearance of the product or details of the product specification dimensions mounting interval lamp type etc The product should be oriented within an angle range of 0 down to 90 horizontal Don t install the product vertically with its longitudinal side in a vertical position If it is installed vertically an insulation failure or electric shock might result For outdo...

Page 5: ...ble for the location Use of an unsuitable type apparatus might cause an explosion or fire The ambient temperature should be within the operating temperature range specified in the instruction manual If the product should be used at a temperature higher than specified an early lighting failure or malfunction might occur or an explosion or fire might result If a product must be oriented in a specifi...

Page 6: ...lace it The LED module design life is 6 0000 hours different from the lighting fitting life when used at an ambient temperature of 30 C 10 hours per day 3 000 hours per year If used at a higher temperature or more hours per year the life would be shortened Have a specialist inspect the product every three years If used for an extended period without inspection a smoke fire or electric shock might ...

Reviews: