Fix the terminal box and the suspension bracket on the mounting surface securely.
NB: For the bracket type, fix it on a vertical mounting surface securely.
Screw suspension pipes A and B into the fitting.
Lift the fitting, fit suspension pipe B to the suspension bracket.
Completely fix the stand pole with the support (not supplied) and prescribed terminal box mounting screws.
Fit the terminal box cap onto the terminal box and turn the fastening ring 90 degrees until the projection aligns with the red mark.
Tighten the locking screws.
Tighten the fixing nuts on the suspension hardware.
NB1: The pipe, locking screws and cross recessed hexagon blots should be tightened securely. Otherwise, the lamp house might fall.
NB2: Caulk the threaded connections.
NB3:
For the direct mount and Pipe pendant type, The lamp house may be installed within an angle range of 0° (down).
NB4:
■
Stanchion Type (Fig. 2: Example LKBB070551)
Fix the clamp with the clamp fixing screw.
Referring to Fig. 2, pass the electric wires (white and red:
power wires, black: grounding wire) through the stand pole
and insert the pole into the terminal box in the arrow
direction.
Tighten the locking screw on the terminal box. Confirm that
the box does not turn.
The positioning box is not a supplied item. Fit the short nipple
and positioning box referring to the attached
Short Nipple
I stallatio Ma ual.
Fix the stand pole with the support (not supplied) and the
positioning box mounting screws completely. (The pole has
four 8 mm-diameter holes arranged at pitches of 85x85 mm
for the positioning box mounting screws.)
After putting the fastening ring around suspension pipe A, screw the terminal box cap onto the suspension pipe. Confirm that the O ring is in
the groove of the terminal box.
Connect the power and grounding wires inside the terminal box and conduct insulation treatment on them. Then, remove the suspension
hook and place the hook in the terminal box cap. The black and white wires are power wires. You need not care about polarity. The green
wire is a grounding wire.
For the bracket type, the lamp house may be installed within an angle range of 0° (down) to 45° (oblique). For the direct mount and
Pipe pendant type, The lamp house may be installed within an angle range of 0° (down).
In the case of the bracket type, install the fitting with the hinge shaft down according to the drawing. Otherwise, a failure might occur.
拡大図
Clamp
Fixing
Screw
Clamp
Screw G3/4
Support (not supplied)
Locking Bolts
Clamp Holder
Stand Pole
Joint box (option)
Short Nipple G3/4
Enlarged View
Terminal Box
Fig. 2
- -