⑦How to use the memory recall function

・The data obtained in the measurement can be recalled and displayed.

・Up to 100 blocks of data or 300 data can be stored and recalled.

・Besides  being  recalled  and  displayed,  the  data  in  memory  can  also  be

printed out.

(Refer to "

⑤ printout")

・The  stored  data  is  recalled  by  pressing  button 

.    The  data  is  recalled

successively if the button is kept pressed.

・The stored data can be recalled while the stopwatch is measuring.

・The data can be stored in memory even while the stopwatch is connected to

the printer to print out the data during the measurement.

・Order of recalling the stored data

・Button operation while the stored data is recalled

With each press of button

 

The data is recalled starting from the oldest one. 
The data is recalled starting from the newest one.

 
When the stopwatch is stopped 
When the stopwatch is in use

Display before recall 
 
Reset 
 
Stopped 
 
Measuring

Button 

A

 

Returning to the dis- 
play before recall 
Returning to the dis- 
play before recall 
Stopping the mea- 
surement

Button 

 

Clearing the data in  
memory 
Returning to the dis- 
play before recall 
Measuring lap/split  
time

Button 

 

Returning to the dis- 
play before recall 
Returning to the dis- 
play before recall 
Returning to the dis- 
play before recall

○When the stopwatch is reset or stopped:

The data is recalled starting from the first data in block "1".

<Ex.) When the display is reset to "00" in  block "4".>

SPLIT

RECALL

BLOCK

LAP

STOP
BATT.
LAP

F

E

SPLIT

RECALL

BLOCK

LAP

STOP
BATT.
LAP

F

E

SPLIT

RECALL

BLOCK

LAP

STOP
BATT.
LAP

F

E

SPLIT

RECALL

BLOCK

LAP

STOP
BATT.
LAP

F

E

SPLIT

RECALL

BLOCK

LAP

STOP
BATT.
LAP

F

E

SPLIT

RECALL

BLOCK
LAP

STOP

BATT.
LAP

F

E

Block no.

Fastest LAP no. Fastest LAP

Lap/Split no.

Split time

Stop time

Recall button

(Fastest lap display)

(Start data) 

(RESET) 

The fastet lap time in this block is  

displayed together with the lap number.

Lap/split data in block "1"

Lap/Split8 Split time 2:1'14"12 

       Lap time   16'42"33

(STOP) 

Stop time 2:11'17"99

Start date

Start time

BLOCK2 

Start data

BLOCK3 

Start data

BLOCK3 

Stop time

C

C

C

C

Button 

C

C

C

C

C

Data in block "1"

Back  to  reset  display  in 
block''4''

○When the stopwatch is measuring:

The data is recalled starting from the newest one.

<Ex.) When the measurement of the third lap /split time in block "4" has been completed>

SPLIT

RECALL

BLOCK

LAP

STOP
BATT.
LAP

F

E

BLOCK3 

Start data

BLOCK3 

Fastest lap

BLOCK3 

Stop time

BLOCK1 
Lap/Split time1

BLOCK4 
Lap/Split time3

BLOCK4 
Lap/Split time3

Lap/Split time1

Lap/Split time3

Lap/Split time2

C

C

C

C

C

C

C

C

C

Data in block "4"

The colon (:) starts flashing.

Fastest lap no.

(Display of the fastest lap time in block "4")

While the stopwatch is measuring, the measurement in  

progress is shown in the bottom row of the display.

⑧How to clear the stored data (All clear of data)

・The memory clear function is useful in the following cases.

a)When the stored data becomes unnecessary.
b)When the residual memory is not sufficient for a new measurement.

・Once the following steps are taken to clear the data, all the stored data is erased from

memory.  The stored data cannot be erased one by one or block by block.

①While the stopwatch is measuring or

when  the  digits  are  not  reset  after
the  end  of  the  measurement,  the
stored  data  cannot  be  erased  from
memory.
In  that  case,  end  the  measurement
and reset the stopwatch by following
the procedure below.

②Press button 

(recall button).

In  the  memory  recall  display,  the
stored data can be erased irrespective of
which data is displayed.

③Keep button 

pressed for more than 1.5 seconds.

While button 

is kept pressed, the display below is shown

with warning beeps.

After 1.5 seconds, the stored data is erased from memory with

a long beep.

All the data is erased from memory and the initial measure-

ment display is shown.

※Unless button 

B is kept pressed for more than 1.5 seconds, the

stored data will not be erased from memory.

SPLIT

RECALL

BLOCK
LAP

STOP
BATT.
LAP

F

E

(Memory clear procedure)

※When the memory clear procedure is performed, the mode  
 mark will move toward the "RECALL" mark.

Button

SPLIT

RECALL

BLOCK

LAP

STOP
BATT.
LAP

F

E

(Digits reset to "00")

SPLIT

RECALL

BLOCK

LAP

STOP
BATT.
LAP

F

E

(Start data)

Button

SPLIT

RECALL

BLOCK

LAP

STOP
BATT.
LAP

F

E

(Digits reset to "00")

Summary of Contents for SP12

Page 1: ...は セイコーデジタルストップウオッチS143 セ イコーシステムプリンタSP12 をお買い上げいただきあ りがとうございました ご使用の前にこの取扱説明書をよくお読みのうえ正しく ご愛用くださいますようお願い申し上げます なおこの 取扱説明書はお手もとに保存し 必要に応じてご覧下さい セイコークオーツデジタル ストップウオッチ セイコーシステムプリンタ 取扱説明書 INSTRUCTION S143 SP12 ...

Page 2: ...ay of the Stopwatch mode Notes on the block of data in memory Standard measurement The SEIKO Stopwatch Cal S143 features a Block Memory stopwatch operation system The data obtained from start till finish of a race is recorded as a block and stored in memory The time and date of starting the measurement of a block of data are automatically stored in memory Before the measurement is started the bloc...

Page 3: ...ata BLOCK3 Start data BLOCK3 Stop time C C C C Button C C C C C Data in block 1 Back to reset display in block 4 When the stopwatch is measuring The data is recalled starting from the newest one Ex When the measurement of the third lap split time in block 4 has been completed SPLIT RECALL BLOCK LAP STOP BATT LAP F E BLOCK3 Start data BLOCK3 Fastest lap BLOCK3 Stop time BLOCK1 Lap Split time1 BLOCK...

Page 4: ... A B A B A 1Press B and the sec ond digits will flash 2Press A in accordance with a time signal to reset the second digits to 00 3Press B and the minute digits will flash 4With each press of A one minute is advanced 7Press B and the year digits will flash 8With each press of A one year advanced 11 Press B and the date digits will flash 12 With each press of A one day is advanced 9Press B nd the mo...

Page 5: ... SPLIT RESET START STOP RECALL PRINTER MODE SELECT CLEAR SET SYSTEM STOPWATCH 300 LAP SPLIT MEMORY WATER RESISTANT SPLIT RECALL BLOCK LAP STOP BATT LAP F E STOP W TIME SYSTEM PRINTER SP12 STOP W S143 Adjusting mark SP12 Power switch Connecting procedure 1 Securely insert both plugs of the connecting cord into the jacks of the stopwatch and printer until they click holding the connecting cord with ...

Page 6: ...6 43 56 7 7 0 07 21 47 8 8 0 07 36 48 Finish time S 0 08 02 58 Ex 1 500m race Printout by the printer Printer switch LAP SPLIT SPLIT LAP SPLIT SPLIT Split time Split time Lap time ID 1 BLOCK 1 Year Month Date 1999 10 10 Start time START 10 19 Split time Lap time SPLIT LAP SPLIT 1 0 18 05 33 LAP 0 18 05 33 SPLIT 2 0 36 37 78 LAP 0 18 32 45 3 0 55 13 11 0 18 35 33 4 1 13 25 34 0 18 12 23 5 1 31 57 5...

Page 7: ...When alkaline manganese batteries are used it can print approx imately 20 000 lines approx 28 rolls It the printer is used at extremely low temperatures the battery power becomes weak and it cannot print as many lines as it prints at normal temperature range It is recommended therefore that alkaline manganese batteries be used at such low temperatures When the following conditions occur with the p...

Page 8: ...actured for swim ming and kitchen work Skindiving without scuba Genuine diving using scuba Button operation when the watch is wet Do not leave the watch in a place where it is subjected to strong magnetism or static electricity Do not leave the watch in a dusty place If your watch is of the fob or pendant type the strap or chain attached to the watch may damage your clothes or injure the hand neck...

Page 9: ... Remove the paper Replace the battery with new ones Remove the paper Make the roll paper round Connect the cord correctly Wipe off the water or foreign matters Inset the paper properly By pressing the start button the data are printed out but the paper is not advanced or is advanced irregularly By pressing the start button no data are printed out and the paper is not advanced at all The paper is s...

Page 10: ...nting Approx 0 02W DC 6 0V 5 Battery life Manganese battery Approx 10 000 lines can be printed Equivalent to approx 14 rolls Alkaline manganese battery Approx 20 000 lines can be printed Equivalent to approx 28 rolls When the printer is connected to stopwatch S111 S119 S123 S124 S143 S701 or S930 and prints out data continuously at 24 the battery life may vary depending on the battery type conditi...

Reviews: